S. M. López-Silva, M. L. Dotor, J. Silveira, R. Giannetti, D. Golmayo, P. Martin, F. Miguel-tobal, A. Bilbao, J. Álvarez-Sala, L. Herrera
{"title":"Transmittance photoplethysmography and pulse oximetry with near infrared laser diodes","authors":"S. M. López-Silva, M. L. Dotor, J. Silveira, R. Giannetti, D. Golmayo, P. Martin, F. Miguel-tobal, A. Bilbao, J. Álvarez-Sala, L. Herrera","doi":"10.1109/IMTC.2004.1351147","DOIUrl":null,"url":null,"abstract":"Photoplethysmography and pulse oximetry are widely used techniques for noninvasive monitoring of heart rate and peripheral oxygen saturation. Over the last years we have been working onto the application of near infrared range wavelengths to replace those of the classical pulse oximeters. The development of laser diodes based sensors, processing algorithms, a calibration procedure, and the comparison with a commercial pulse oximeter, have been followed by a set of experimental studies. The results exposed here demonstrate the applicability of transmittance photoplethysmography and pulse oximetry using laser diodes emitting at specific wavelengths for a wide range of situations.","PeriodicalId":386903,"journal":{"name":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2004.1351147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Photoplethysmography and pulse oximetry are widely used techniques for noninvasive monitoring of heart rate and peripheral oxygen saturation. Over the last years we have been working onto the application of near infrared range wavelengths to replace those of the classical pulse oximeters. The development of laser diodes based sensors, processing algorithms, a calibration procedure, and the comparison with a commercial pulse oximeter, have been followed by a set of experimental studies. The results exposed here demonstrate the applicability of transmittance photoplethysmography and pulse oximetry using laser diodes emitting at specific wavelengths for a wide range of situations.