{"title":"Application guidelines for dry-type distribution power transformers","authors":"P. Sen","doi":"10.1109/ICPS.2003.1201495","DOIUrl":null,"url":null,"abstract":"A large number of distribution transformers, currently utilized in low voltage (LV) power systems are of dry-type design. This includes, the IEEE Class II ventilated dry-type design with 3-phase kVA ratings in the approximate range of 500 kVA - 2.5 MVA and primary voltage ratings ranging from 4.16 kV to 34.5 kV and the secondary voltage ratings of 600 V and below. This paper presents a comprehensive review of dry-type transformers design and provides some application guidelines including insulation system characteristics; BIL; losses, overloading, and loss-of life; and price.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.2003.1201495","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

A large number of distribution transformers, currently utilized in low voltage (LV) power systems are of dry-type design. This includes, the IEEE Class II ventilated dry-type design with 3-phase kVA ratings in the approximate range of 500 kVA - 2.5 MVA and primary voltage ratings ranging from 4.16 kV to 34.5 kV and the secondary voltage ratings of 600 V and below. This paper presents a comprehensive review of dry-type transformers design and provides some application guidelines including insulation system characteristics; BIL; losses, overloading, and loss-of life; and price.
干式配电变压器使用指南
目前在低压电力系统中使用的配电变压器大量采用干式设计。这包括IEEE II类通风干式设计,其三相kVA额定值约为500 kVA - 2.5 MVA,一次额定电压范围为4.16 kV至34.5 kV,二次额定电压为600 V及以下。本文对干式变压器的设计进行了全面的综述,并提出了一些应用准则,包括绝缘系统特性;基本脉冲电平;损失、超载和生命损失;和价格。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信