{"title":"Control of the energy performance of production facilities","authors":"L. Davydenko, V. Rozen, V. Davydenko, N. Davydenko","doi":"10.1109/ESS50319.2020.9160156","DOIUrl":null,"url":null,"abstract":"The article deals with the issue of detecting the presence (absence) of a tendency to improve the energy performance of production facilities in accordance with the requirements of the ISO 50000 series, as well as the moments of inefficient energy consumption process. For this purpose, the control procedure of the energy performance, which provides an analysis of the dynamics of the specific energy consumption and is based on the use of Shewhart charts, is proposed. The limits of regulation of the Shewhart charts are set using the Six Sigma approach. The interpretation of the obtained zones and sub-zones in terms of energy efficiency is proposed. This allows performing a qualitative assessment of the energy performance of the facility. Energy efficiency zones are used as standards for specific energy consumption. Ways to setup alarms about the exceeding the standards that take into consideration the actual energy performance of the controlled facility and the target of its increasing are suggested. The method of comparative analysis of the energy performance of the group of facilities is proposed. For this purpose, the energy efficiency zones of better facility are suggested to use as standard. This approach is applied to control the energy performance of water intakes of the municipal water supply system. The analysis of the results allows performing a qualitative assessment of the energy performance of each water intake and identifying the presence (absence) of tendencies for its improvement (deterioration), including, with taking into consideration the achievements of better water intake. Two steps of the alarms setup for each water intake are proposed in order to inform the energy manager of the control results. The application of the proposed approach provides control over the keeping of the actual energy performance to the established standards, allows determining new targets for its improvement, which contributes to the continuous improvement of energy efficiency of the facility.","PeriodicalId":169630,"journal":{"name":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS50319.2020.9160156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article deals with the issue of detecting the presence (absence) of a tendency to improve the energy performance of production facilities in accordance with the requirements of the ISO 50000 series, as well as the moments of inefficient energy consumption process. For this purpose, the control procedure of the energy performance, which provides an analysis of the dynamics of the specific energy consumption and is based on the use of Shewhart charts, is proposed. The limits of regulation of the Shewhart charts are set using the Six Sigma approach. The interpretation of the obtained zones and sub-zones in terms of energy efficiency is proposed. This allows performing a qualitative assessment of the energy performance of the facility. Energy efficiency zones are used as standards for specific energy consumption. Ways to setup alarms about the exceeding the standards that take into consideration the actual energy performance of the controlled facility and the target of its increasing are suggested. The method of comparative analysis of the energy performance of the group of facilities is proposed. For this purpose, the energy efficiency zones of better facility are suggested to use as standard. This approach is applied to control the energy performance of water intakes of the municipal water supply system. The analysis of the results allows performing a qualitative assessment of the energy performance of each water intake and identifying the presence (absence) of tendencies for its improvement (deterioration), including, with taking into consideration the achievements of better water intake. Two steps of the alarms setup for each water intake are proposed in order to inform the energy manager of the control results. The application of the proposed approach provides control over the keeping of the actual energy performance to the established standards, allows determining new targets for its improvement, which contributes to the continuous improvement of energy efficiency of the facility.
控制生产设备的能源性能
本文论述了按照ISO 50000系列要求检测生产设施是否有提高能源性能的趋势,以及低效能耗过程的时刻。为此,提出了基于Shewhart图的能源绩效控制程序,该程序提供了对比能耗动态的分析。使用六西格玛方法设定了休哈特图的调节极限。从能源效率的角度对得到的分区和分区进行了解释。这样就可以对设施的能源性能进行定性评估。能源效率区被用作特定能源消耗的标准。结合被控设备的实际能源性能和提高目标,提出了超标报警的设置方法。提出了对机组的能源性能进行比较分析的方法。为此,建议采用能效较好的设施作为标准。将该方法应用于城市供水系统取水口的能源性能控制。对结果的分析允许对每次取水的能量表现进行定性评估,并确定其改善(恶化)趋势的存在(不存在),包括考虑到更好的取水所取得的成就。为了通知能源管理人员控制结果,建议为每个取水口设置警报的两个步骤。采用建议的方法可以控制实际的能源表现,使其符合既定的标准,从而确定新的改善目标,从而有助于不断提高设施的能源效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信