New strategy for generation of reference current in Active Power Filters with distortion in line voltage

R. Panigrahi, P. C. Panda, B. Subudhi
{"title":"New strategy for generation of reference current in Active Power Filters with distortion in line voltage","authors":"R. Panigrahi, P. C. Panda, B. Subudhi","doi":"10.1109/ICIINFS.2012.6304814","DOIUrl":null,"url":null,"abstract":"This paper describes a new control strategy to improve the performance of shunt Active Power Filter (SAPF). The performance of an active power filter depends on the inverter characteristics, applied control method, and the accuracy of the reference signal generation. The accuracy of the reference signal generator is the most critical item in determining the performance of APF. The new control strategy is based on the combination of low pass filter and Kalman filter based reference current generation. The performance of the reference signal generator was verified through MATLAB. The simulation results confirm that our reference signal generator can be used successfully and perfectly.","PeriodicalId":171993,"journal":{"name":"2012 IEEE 7th International Conference on Industrial and Information Systems (ICIIS)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 7th International Conference on Industrial and Information Systems (ICIIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIINFS.2012.6304814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper describes a new control strategy to improve the performance of shunt Active Power Filter (SAPF). The performance of an active power filter depends on the inverter characteristics, applied control method, and the accuracy of the reference signal generation. The accuracy of the reference signal generator is the most critical item in determining the performance of APF. The new control strategy is based on the combination of low pass filter and Kalman filter based reference current generation. The performance of the reference signal generator was verified through MATLAB. The simulation results confirm that our reference signal generator can be used successfully and perfectly.
电压失真有源滤波器基准电流产生的新策略
提出了一种提高并联型有源电力滤波器性能的新控制策略。有源电力滤波器的性能取决于逆变器的特性、应用的控制方法和参考信号产生的精度。参考信号发生器的精度是决定有源滤波器性能的最关键因素。新的控制策略是基于低通滤波器和卡尔曼滤波器相结合的参考电流产生方法。通过MATLAB对参考信号发生器的性能进行了验证。仿真结果表明,所设计的参考信号发生器可以很好地正常使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信