Estimation and Validation of Junction Temperature of IGBT for Grid-Connected PV Applications

Mohan P. Thakre, M. Patil, Y. Mahadik
{"title":"Estimation and Validation of Junction Temperature of IGBT for Grid-Connected PV Applications","authors":"Mohan P. Thakre, M. Patil, Y. Mahadik","doi":"10.1109/IEMRE52042.2021.9386736","DOIUrl":null,"url":null,"abstract":"Recent advances in power electronics have led to increased use of electricity from renewable energy systems, such as photovoltaic (PV) as well as wind energy systems. Developments in power semiconductor technology, i.e. a wide band gap, have increased the conversion efficiency of power electronics to more than 98%, however the dependability with power electronics is becoming a major concern. Junction Temperature is the primary parameter that affects this same reliability of the IGBT. Mission profile (Solar Irradiance & Ambient Temperature) variation throughout junction temperature tends to lead to mechanical failure (Bond wire lift off, solder fatigue etc.). Therefore, in order to assess reliability, the junction temperature needs to be estimated. But the junction temperature cannot be calculated directly, it requires an indirect method of estimation and validation. The 3 kW grid connected to the PV Inverter is however discussed in this paper. PV Inverter consists of four IGW30N60H3 IGBTs from the Infmeon manufacturer. Annual mission profile data is logged in Hyderabad, India. Foster electro thermal modeling (ETM) is held out for junction temperature evaluation. Validation for the estimated junction temperature is required as estimated by indirect method. Finally, the estimated junction temperature is validated by correlation with annual solar irradiance, ambient temperature and case temperature.","PeriodicalId":202287,"journal":{"name":"2021 Innovations in Energy Management and Renewable Resources(52042)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Innovations in Energy Management and Renewable Resources(52042)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMRE52042.2021.9386736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Recent advances in power electronics have led to increased use of electricity from renewable energy systems, such as photovoltaic (PV) as well as wind energy systems. Developments in power semiconductor technology, i.e. a wide band gap, have increased the conversion efficiency of power electronics to more than 98%, however the dependability with power electronics is becoming a major concern. Junction Temperature is the primary parameter that affects this same reliability of the IGBT. Mission profile (Solar Irradiance & Ambient Temperature) variation throughout junction temperature tends to lead to mechanical failure (Bond wire lift off, solder fatigue etc.). Therefore, in order to assess reliability, the junction temperature needs to be estimated. But the junction temperature cannot be calculated directly, it requires an indirect method of estimation and validation. The 3 kW grid connected to the PV Inverter is however discussed in this paper. PV Inverter consists of four IGW30N60H3 IGBTs from the Infmeon manufacturer. Annual mission profile data is logged in Hyderabad, India. Foster electro thermal modeling (ETM) is held out for junction temperature evaluation. Validation for the estimated junction temperature is required as estimated by indirect method. Finally, the estimated junction temperature is validated by correlation with annual solar irradiance, ambient temperature and case temperature.
并网光伏应用中IGBT结温的估算与验证
电力电子技术的最新进展导致可再生能源系统的电力使用增加,例如光伏(PV)和风能系统。功率半导体技术的发展,即宽带隙,使电力电子设备的转换效率提高到98%以上,但是电力电子设备的可靠性正在成为一个主要问题。结温是影响IGBT可靠性的主要参数。任务剖面(太阳辐照度和环境温度)在整个结温中的变化往往会导致机械故障(键合线脱落,焊料疲劳等)。因此,为了评估可靠性,需要对结温进行估计。但结温不能直接计算,需要间接的估计和验证方法。然而,本文讨论了与光伏逆变器连接的3kw电网。光伏逆变器由4台IGW30N60H3型igbt组成。年度任务概况数据记录在印度海得拉巴。福斯特电热模型(ETM)提出了结温评估。需要对间接方法估计的结温进行验证。最后,通过与年太阳辐照度、环境温度和壳体温度的相关性验证了估算结温。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信