{"title":"Electric detection of divers in harbor environments","authors":"R. Lennartsson, E. Dalberg, T. Fristedt, E. Nolander, L. Persson","doi":"10.23919/OCEANS.2009.5422404","DOIUrl":null,"url":null,"abstract":"In this paper we compare the detection performance of underwater electric-field sensors against divers using three different detection algorithms (matched filter, non-coherent and quadrature detectors). The detection performance is quantified and presented as ROC-curves. The empirical results are based on measurements of signatures from divers with open circuit breathing systems. They were performed during two sea-trials in diverse environments. One site is a remote area with relatively low anthropogenic activity and the other site is a busy container terminal in the port of Gothenburg, both sites in Sweden. Of the three detectors evaluated, no single detector stands out. This may imply the usefulness of fusion as a means of improving the performance in the future. In Gothenburg harbor detection of divers can be performed at signal-to-noise ratios from −20 to 0 dB, depending on the noise situation. In addition to detection, it is found that it is possible to classify a contact as a diver.","PeriodicalId":119977,"journal":{"name":"OCEANS 2009","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OCEANS 2009","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/OCEANS.2009.5422404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
In this paper we compare the detection performance of underwater electric-field sensors against divers using three different detection algorithms (matched filter, non-coherent and quadrature detectors). The detection performance is quantified and presented as ROC-curves. The empirical results are based on measurements of signatures from divers with open circuit breathing systems. They were performed during two sea-trials in diverse environments. One site is a remote area with relatively low anthropogenic activity and the other site is a busy container terminal in the port of Gothenburg, both sites in Sweden. Of the three detectors evaluated, no single detector stands out. This may imply the usefulness of fusion as a means of improving the performance in the future. In Gothenburg harbor detection of divers can be performed at signal-to-noise ratios from −20 to 0 dB, depending on the noise situation. In addition to detection, it is found that it is possible to classify a contact as a diver.