Microplastic Removal in Krueng Aceh River Water Using Ultrafiltration Membrane from Polyethersulfone Polymer (PES)

Haifa Dzihninafira, Abd Mujahid Hamdan, Fachrul Razi
{"title":"Microplastic Removal in Krueng Aceh River Water Using Ultrafiltration Membrane from Polyethersulfone Polymer (PES)","authors":"Haifa Dzihninafira, Abd Mujahid Hamdan, Fachrul Razi","doi":"10.20885/ijca.vol6.iss2.art7","DOIUrl":null,"url":null,"abstract":"The Company's input pipes contained microplastics, per the preliminary test findings. While the water yield produced by PDAM Tirta Daroy contains 150 particles/L, the Tirta Daroy Drinking Water Area has 275 particles/L. Microplastics found in the water pose a major risk to living beings if they are consumed. This work aims to characterize the properties, flux, and polyethersulfone (PES) membrane rejection coefficient, which were made utilizing the phase inversion technique with a solvent and additives called N,N-dimethylformamide (DMF). In Sungai Krueng Aceh, titanium dioxide (TiO2) is utilized to filter out microplastics from the water. Results of Scanning Electron Microscopy (SEM) examination of Membrane Morphology demonstrate that the resulting membrane is an asymmetrical membrane of two layers, the upper layer relatively thin and the lower layer porous. When compared to the PES membrane when it was 15% DMF/TiO2, the 20% DMF/TiO2 membrane exhibits a finger-like cross-sectional structure called a macrovoid) with more and larger numbers. Analysis of the microplastic rejection coefficients proved the effectiveness of PES, DMF, and TiO2 membranes in removing microplastics. Results of tests on the effectiveness of rejecting microplastics after undergoing process filtration with a microplastic rejection coefficient of 94% and 14.2 particles/L utilizing a 20% PES/DMF/TiO2 membrane Performance of PES membranes: The PES membrane with 20% DMF/TiO2 has a water flux of 0.467 L/m2.hour compared to 15% DMF/TiO2 0.733 L/m2.hour. This study's findings on membrane Ultrafiltration have the potential to be used as a water filter standard in PDAM.","PeriodicalId":215410,"journal":{"name":"IJCA (Indonesian Journal of Chemical Analysis)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJCA (Indonesian Journal of Chemical Analysis)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20885/ijca.vol6.iss2.art7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Company's input pipes contained microplastics, per the preliminary test findings. While the water yield produced by PDAM Tirta Daroy contains 150 particles/L, the Tirta Daroy Drinking Water Area has 275 particles/L. Microplastics found in the water pose a major risk to living beings if they are consumed. This work aims to characterize the properties, flux, and polyethersulfone (PES) membrane rejection coefficient, which were made utilizing the phase inversion technique with a solvent and additives called N,N-dimethylformamide (DMF). In Sungai Krueng Aceh, titanium dioxide (TiO2) is utilized to filter out microplastics from the water. Results of Scanning Electron Microscopy (SEM) examination of Membrane Morphology demonstrate that the resulting membrane is an asymmetrical membrane of two layers, the upper layer relatively thin and the lower layer porous. When compared to the PES membrane when it was 15% DMF/TiO2, the 20% DMF/TiO2 membrane exhibits a finger-like cross-sectional structure called a macrovoid) with more and larger numbers. Analysis of the microplastic rejection coefficients proved the effectiveness of PES, DMF, and TiO2 membranes in removing microplastics. Results of tests on the effectiveness of rejecting microplastics after undergoing process filtration with a microplastic rejection coefficient of 94% and 14.2 particles/L utilizing a 20% PES/DMF/TiO2 membrane Performance of PES membranes: The PES membrane with 20% DMF/TiO2 has a water flux of 0.467 L/m2.hour compared to 15% DMF/TiO2 0.733 L/m2.hour. This study's findings on membrane Ultrafiltration have the potential to be used as a water filter standard in PDAM.
聚醚砜聚合物(PES)超滤膜去除Krueng Aceh河水中的微塑料
根据初步测试结果,该公司的输入管道含有微塑料。而PDAM第尔达河的产水量为150粒/升,第尔达河饮用水区为275粒/升。水中发现的微塑料如果被食用,将对生物构成重大威胁。这项工作的目的是表征性能,通量和聚醚砜(PES)膜的过滤系数,利用相转化技术与溶剂和添加剂称为N,N-二甲基甲酰胺(DMF)。在Sungai Krueng Aceh,二氧化钛(TiO2)被用来过滤水中的微塑料。扫描电镜(SEM)对膜的形貌进行了检测,结果表明所制得的膜为两层不对称膜,上层相对较薄,下层多孔。与掺量为15% DMF/TiO2的PES膜相比,掺量为20% DMF/TiO2的PES膜呈现出手指状的横截面结构(称为大空洞),且数量更多、更大。对PES、DMF和TiO2膜的微塑料去除系数进行了分析,证明了三种膜对微塑料的去除效果。采用20% PES/DMF/TiO2膜对微塑料进行工艺过滤,截留系数为94%,截留14.2颗粒/L,截留效果试验结果PES膜的性能:含20% DMF/TiO2的PES膜的水通量为0.467 L/m2。15% DMF/TiO2为0.733 L/m2.hour。本研究的研究结果有可能作为PDAM的水过滤标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信