New concept to develop a safety sensor network for continuous noninvasive blood pressure monitoring

H. Sheng, M. Schwarz, J. Börcsök
{"title":"New concept to develop a safety sensor network for continuous noninvasive blood pressure monitoring","authors":"H. Sheng, M. Schwarz, J. Börcsök","doi":"10.1109/ETFA.2012.6489742","DOIUrl":null,"url":null,"abstract":"This paper proposes a continuous, non-invasive blood pressure monitoring system concept, which uses a safety microprocessor to connect sensors for building a body sensor network. The changes in Pulse Transit Time (PTT) can be detected with the sensor network. The microprocessor gathers the PTT and other vital signs of the patient to derive changes in blood pressure. Through the new Bluetooth protocol for safety systems, the current blood pressure value can be sent to a variety of terminals present in the wireless network, such as mobile phone, PC and medical monitoring systems. The 1oo2 architecture of the used microprocessor can provide high safety to a rating of safety integrity level 3 (SIL3), thus the whole network can meet the safety required in medical care systems.","PeriodicalId":222799,"journal":{"name":"Proceedings of 2012 IEEE 17th International Conference on Emerging Technologies & Factory Automation (ETFA 2012)","volume":"431 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2012 IEEE 17th International Conference on Emerging Technologies & Factory Automation (ETFA 2012)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ETFA.2012.6489742","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes a continuous, non-invasive blood pressure monitoring system concept, which uses a safety microprocessor to connect sensors for building a body sensor network. The changes in Pulse Transit Time (PTT) can be detected with the sensor network. The microprocessor gathers the PTT and other vital signs of the patient to derive changes in blood pressure. Through the new Bluetooth protocol for safety systems, the current blood pressure value can be sent to a variety of terminals present in the wireless network, such as mobile phone, PC and medical monitoring systems. The 1oo2 architecture of the used microprocessor can provide high safety to a rating of safety integrity level 3 (SIL3), thus the whole network can meet the safety required in medical care systems.
开发安全传感器网络的新概念,用于连续无创血压监测
本文提出了一种连续、无创血压监测系统的概念,该系统采用安全微处理器连接传感器,构建人体传感器网络。通过传感器网络可以检测到脉冲传输时间(PTT)的变化。微处理器收集PTT和病人的其他生命体征,得出血压的变化。通过新的安全系统蓝牙协议,可以将当前的血压值发送到无线网络中的各种终端,例如手机,PC和医疗监控系统。所使用的微处理器的1002架构可以提供高安全性,安全完整性等级为3 (SIL3),因此整个网络可以满足医疗保健系统的安全要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信