M. Aleksa, R. Assmann, W. Coosemans, G. Guignard, N. Leros, M. Mayoud, S. Redaelli, F. Ruggiero, S. Russenschuck, D. Schulte, I. Wilson, F. Zimmermann
{"title":"The CLIC study of magnet stability and time-dependent luminosity performance","authors":"M. Aleksa, R. Assmann, W. Coosemans, G. Guignard, N. Leros, M. Mayoud, S. Redaelli, F. Ruggiero, S. Russenschuck, D. Schulte, I. Wilson, F. Zimmermann","doi":"10.1109/PAC.2001.988249","DOIUrl":null,"url":null,"abstract":"The present parameters of the CLIC study require the collision of small emittance beams with a vertical spot size of 1 nm. The tolerances on vertical quadrupole vibration (above a few Hz) are as small as a few nm in the linac and most of the Final Focus. The final focusing quadrupole has a stability requirement of 4 nm in the horizontal and 0.2 nm in the vertical direction. Those tolerances can only be achieved with the use of damped support structures for CLIC. A study has been set-up at CERN to explore the application of stabilization devices from specialized industry and to predict the time-dependent luminosity performance for CLIC. The results will guide the specification of required technological improvements and will help to verify the feasibility of the present CLIC parameters.","PeriodicalId":313758,"journal":{"name":"PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.2001.988249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
The present parameters of the CLIC study require the collision of small emittance beams with a vertical spot size of 1 nm. The tolerances on vertical quadrupole vibration (above a few Hz) are as small as a few nm in the linac and most of the Final Focus. The final focusing quadrupole has a stability requirement of 4 nm in the horizontal and 0.2 nm in the vertical direction. Those tolerances can only be achieved with the use of damped support structures for CLIC. A study has been set-up at CERN to explore the application of stabilization devices from specialized industry and to predict the time-dependent luminosity performance for CLIC. The results will guide the specification of required technological improvements and will help to verify the feasibility of the present CLIC parameters.