Study of on-line monitoring method of partial discharge for power transformers based on RFCT and microstrip antenna

Cheng Yonghong, Chen Yu, Liu Tong, Xun Xiaowei, Ji Linlie, Chen Wei, Chen Lixin
{"title":"Study of on-line monitoring method of partial discharge for power transformers based on RFCT and microstrip antenna","authors":"Cheng Yonghong, Chen Yu, Liu Tong, Xun Xiaowei, Ji Linlie, Chen Wei, Chen Lixin","doi":"10.1109/EEIC.2005.1566268","DOIUrl":null,"url":null,"abstract":"It is an important means for partial discharge (PD) on-line monitoring of oil-immersed power transformers in order to evaluating the insulation condition. Radio frequency current transducers (RFCT) are applied to couple the PD pulse current signal, and the difference-balance pairs (one of three-phase bushing-tap grounding terminals respectively corresponded with the neutral or iron core terminal) are selected, and high speed data acquisition card is adopt to sample the PD signal (>10MS/s) from the balance pair, and further amplitude modulation, phase modulation and difference arithmetic is designed, then external electromagnetic interference is effectively suppressed and it is propitious to extracting PD pulses and judge the PD occurrence place. The wideband PD couplers based on microstrip antenna are also applied to detect the high frequency PD pulse signal. Four sensors are installed at the special parts on the transformer where PD electromagnetic wave signal can be received, then the signal is transmitted to the input analog channel of the oscilloscope (>IGS/s). So single PD waveform analysis throughout more wide frequency band can be done, and further PD fault location can also be realized. The PD on-line monitoring system based on the above two monitoring methods for in-service transformer has also been developed and installed at one main transformer in a plant (220/18RV, 360MVA, three phase and dual winding)","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2005.1566268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

It is an important means for partial discharge (PD) on-line monitoring of oil-immersed power transformers in order to evaluating the insulation condition. Radio frequency current transducers (RFCT) are applied to couple the PD pulse current signal, and the difference-balance pairs (one of three-phase bushing-tap grounding terminals respectively corresponded with the neutral or iron core terminal) are selected, and high speed data acquisition card is adopt to sample the PD signal (>10MS/s) from the balance pair, and further amplitude modulation, phase modulation and difference arithmetic is designed, then external electromagnetic interference is effectively suppressed and it is propitious to extracting PD pulses and judge the PD occurrence place. The wideband PD couplers based on microstrip antenna are also applied to detect the high frequency PD pulse signal. Four sensors are installed at the special parts on the transformer where PD electromagnetic wave signal can be received, then the signal is transmitted to the input analog channel of the oscilloscope (>IGS/s). So single PD waveform analysis throughout more wide frequency band can be done, and further PD fault location can also be realized. The PD on-line monitoring system based on the above two monitoring methods for in-service transformer has also been developed and installed at one main transformer in a plant (220/18RV, 360MVA, three phase and dual winding)
基于RFCT和微带天线的电力变压器局部放电在线监测方法研究
对油浸式电力变压器进行局部放电在线监测,是评估变压器绝缘状况的重要手段。采用射频电流传感器(RFCT)对PD脉冲电流信号进行耦合,选择差分平衡对(分别与中性点或铁芯端子对应的三相套管抽头接地端子之一),采用高速数据采集卡对平衡对PD信号进行采样(>10MS/s),并进一步设计了调幅、调相和差分算法;有效地抑制了外界电磁干扰,有利于PD脉冲的提取和PD发生位置的判断。基于微带天线的宽带PD耦合器也被用于检测高频PD脉冲信号。在变压器上可接收PD电磁波信号的专用部位安装4个传感器,将信号送入示波器输入模拟通道(>IGS/s)。因此,可以在更宽的频带范围内进行单次PD波形分析,并进一步实现PD故障定位。基于上述两种监测方法的在役变压器PD在线监测系统也已开发并安装在某厂一台主变压器(220/18RV, 360MVA,三相双绕组)上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信