Current and voltage transformers

J. Gers, E. J. Holmes
{"title":"Current and voltage transformers","authors":"J. Gers, E. J. Holmes","doi":"10.1049/PBPO065E_ch4","DOIUrl":null,"url":null,"abstract":"Current or voltage instrument transformers are necessary to isolate the protection, control and measurement equipment from the high voltages of a power system, and for supplying the equipment with the appropriate values of current and voltage generally these are 1 or 5 A for the current coils, and 120 V for the voltage coils. The behaviour of current and voltage transformers (VTs) during and after the occurrence of a fault is critical in electrical protection because errors in the signal from a transformer can cause maloperation of the relays. In addition, factors such as the transient period and saturation must be taken into account when selecting the appropriate transformer. When only voltage or current magnitudes are required to operate a relay, the relative direction of the current flow in the transformer windings is not important. However, the polarity must be kept in mind when the relays compare the sum or difference of the currents.","PeriodicalId":396276,"journal":{"name":"Protection of Electricity Distribution Networks","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Protection of Electricity Distribution Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/PBPO065E_ch4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Current or voltage instrument transformers are necessary to isolate the protection, control and measurement equipment from the high voltages of a power system, and for supplying the equipment with the appropriate values of current and voltage generally these are 1 or 5 A for the current coils, and 120 V for the voltage coils. The behaviour of current and voltage transformers (VTs) during and after the occurrence of a fault is critical in electrical protection because errors in the signal from a transformer can cause maloperation of the relays. In addition, factors such as the transient period and saturation must be taken into account when selecting the appropriate transformer. When only voltage or current magnitudes are required to operate a relay, the relative direction of the current flow in the transformer windings is not important. However, the polarity must be kept in mind when the relays compare the sum or difference of the currents.
电流电压互感器
电流或电压互感器是必要的,它将保护、控制和测量设备与电力系统的高压隔离开来,并为设备提供适当的电流和电压值,电流线圈通常为1或5 a,电压线圈为120 V。在发生故障期间和之后,电流和电压互感器(vt)的行为在电气保护中是至关重要的,因为来自变压器的信号中的错误可能导致继电器的误操作。此外,在选择合适的变压器时,还必须考虑到暂态时间和饱和等因素。当只需要电压或电流大小来操作继电器时,变压器绕组中电流流动的相对方向并不重要。然而,当继电器比较电流的和或差时,必须记住极性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信