{"title":"Reducing energy consumption of mine cooling systems by controlling chilled water demand of mobile cooling units","authors":"P. Maré, J. Marais, C. Kriel","doi":"10.1109/ICUE.2014.6904189","DOIUrl":null,"url":null,"abstract":"Energy costs are increasing rapidly. Energy efficiency strategies are required to reduce electricity consumption for energy intensive operations. Cooling systems of deep level mines consume approximately 25% of their total electricity consumption. Cold water supplied by these systems is reticulated throughout the mine. Water reticulation can account for a further 42% of the total electricity consumption of a typical deep level mine. Underground working areas in deep level mines must be cooled to account for temperatures of up to 60 °C. Mobile cooling units are often used to cool underground working areas. These units require significant amounts of chilled water. Adequate supply of chilled water to these units is crucial to comply with health and safety regulations. It is often found that the water supply to mobile cooling units is not properly managed. Energy savings can be achieved on the cooling systems as well as the reticulation systems by reducing the water consumption of mobile cooling units. Various valves were identified as possible equipment to be used to manage water consumption on mobile cooling units. A case study proved that flow reductions on the mobile cooling units are possible. Worker safety and mine production was not affected by the installations. Electrical energy savings were achieved through reduced pumping and reduction in refrigeration energy consumption. Water consumption for one mobile cooling unit was reduced by 237 kℓ/day. This is equivalent to an average saving of 37.5 kW per unit. This saving includes the reduced power consumption on the chillers and pumps. Installing the valve on 26 MCUs would potentially result in a total saving of approximately 1 MW, an annual saving of R 2.8 million.","PeriodicalId":149169,"journal":{"name":"2014 International Conference on the Eleventh industrial and Commercial Use of Energy","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on the Eleventh industrial and Commercial Use of Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICUE.2014.6904189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
Energy costs are increasing rapidly. Energy efficiency strategies are required to reduce electricity consumption for energy intensive operations. Cooling systems of deep level mines consume approximately 25% of their total electricity consumption. Cold water supplied by these systems is reticulated throughout the mine. Water reticulation can account for a further 42% of the total electricity consumption of a typical deep level mine. Underground working areas in deep level mines must be cooled to account for temperatures of up to 60 °C. Mobile cooling units are often used to cool underground working areas. These units require significant amounts of chilled water. Adequate supply of chilled water to these units is crucial to comply with health and safety regulations. It is often found that the water supply to mobile cooling units is not properly managed. Energy savings can be achieved on the cooling systems as well as the reticulation systems by reducing the water consumption of mobile cooling units. Various valves were identified as possible equipment to be used to manage water consumption on mobile cooling units. A case study proved that flow reductions on the mobile cooling units are possible. Worker safety and mine production was not affected by the installations. Electrical energy savings were achieved through reduced pumping and reduction in refrigeration energy consumption. Water consumption for one mobile cooling unit was reduced by 237 kℓ/day. This is equivalent to an average saving of 37.5 kW per unit. This saving includes the reduced power consumption on the chillers and pumps. Installing the valve on 26 MCUs would potentially result in a total saving of approximately 1 MW, an annual saving of R 2.8 million.
能源成本正在迅速上升。能源效率战略需要减少能源密集型业务的电力消耗。深层矿井的冷却系统耗电量约占其总耗电量的25%。这些系统提供的冷水在整个矿井中网状分布。在一个典型的深井矿井中,水网还可以占总用电量的42%。深埋矿井的地下工作区域必须冷却,以适应高达60°C的温度。移动冷却装置通常用于冷却地下工作区域。这些装置需要大量的冷冻水。为这些设备提供充足的冷冻水对于遵守健康和安全法规至关重要。人们经常发现流动冷却装置的供水管理不当。通过减少移动冷却装置的用水量,可以在冷却系统以及网状系统上实现节能。各种阀门被确定为可能用于管理移动冷却装置的水消耗的设备。一个案例研究证明,减少流动冷却装置的流量是可能的。工人安全和矿山生产没有受到这些设施的影响。通过减少泵送和减少制冷能耗,实现了电能节约。1台移动冷却机组日耗水量减少237 k / l。这相当于每台机组平均节省37.5千瓦。这种节省包括减少了冷水机组和泵的电力消耗。将阀门安装在26个mcu上,可能会节省大约1兆瓦的电力,每年节省280万卢比。