Evaluation of a novel tubular sample holder for dielectric measurements with Abdulnour's method

A. Rotava, L. E. Borges, M. Dias, Jose C. A. Santos
{"title":"Evaluation of a novel tubular sample holder for dielectric measurements with Abdulnour's method","authors":"A. Rotava, L. E. Borges, M. Dias, Jose C. A. Santos","doi":"10.1109/IMOC.2013.6646604","DOIUrl":null,"url":null,"abstract":"This paper assesses the accuracy of a rectangular waveguide pierced by a tubular load sample holder for measuring liquid materials at high temperatures with a formulation based on Abdulnour's method. The measurement technique is derived from the transmission line method. The sample holder is adapted from a section of a rectangular waveguide pierced by a tubular load for high temperature measurements at 2.45 GHz. Simulations of the loaded sample holder are carried out with CST Microwave Studio® for several values of sample permittivity. The accuracy of the technique is evaluated by comparing these values to those obtained from Abdulnour's extraction model. It is shown that by properly choosing a set of calibration standards the technique can be quite accurate.","PeriodicalId":395359,"journal":{"name":"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)","volume":"144 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMOC.2013.6646604","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper assesses the accuracy of a rectangular waveguide pierced by a tubular load sample holder for measuring liquid materials at high temperatures with a formulation based on Abdulnour's method. The measurement technique is derived from the transmission line method. The sample holder is adapted from a section of a rectangular waveguide pierced by a tubular load for high temperature measurements at 2.45 GHz. Simulations of the loaded sample holder are carried out with CST Microwave Studio® for several values of sample permittivity. The accuracy of the technique is evaluated by comparing these values to those obtained from Abdulnour's extraction model. It is shown that by properly choosing a set of calibration standards the technique can be quite accurate.
用Abdulnour方法评价一种新型管状样品架的介电测量
本文采用基于Abdulnour方法的配方,评估了管状负载样架刺穿的矩形波导在高温下测量液体材料的精度。该测量技术来源于传输线法。样品支架采用矩形波导的一段,经管状负载刺穿,用于2.45 GHz的高温测量。用CST Microwave Studio®对加载的样品支架进行了几种样品介电常数值的模拟。通过将这些值与从Abdulnour提取模型中获得的值进行比较,评估了该技术的准确性。结果表明,通过正确选择一套校准标准,该技术可以相当准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信