Level-2 Calorimeter Trigger Upgrade at CDF

A. Bhatti, A. Canepa, M. Casarsa, M. Convery, G. Cortiana, M. Dell'Orso, S. Donati, G. Flanagan, H. Frisch, T. Fukun, P. Giannetti, V. Greco, M. Jones, D. Krop, T. Liu, D. Lucchesi, D. Pantano, M. Piendibene, L. Ristori, L. Rogondino, V. Rusu, L. Sartori, V. Veszpremi, M. Vidal, L. Zhou
{"title":"Level-2 Calorimeter Trigger Upgrade at CDF","authors":"A. Bhatti, A. Canepa, M. Casarsa, M. Convery, G. Cortiana, M. Dell'Orso, S. Donati, G. Flanagan, H. Frisch, T. Fukun, P. Giannetti, V. Greco, M. Jones, D. Krop, T. Liu, D. Lucchesi, D. Pantano, M. Piendibene, L. Ristori, L. Rogondino, V. Rusu, L. Sartori, V. Veszpremi, M. Vidal, L. Zhou","doi":"10.1109/nssmic.2006.354160","DOIUrl":null,"url":null,"abstract":"The CDF Run II level-2 calorimeter trigger is implemented in hardware and is based on a simple algorithm used in Run I. This system has worked well for Run II at low luminosity. However, as the Tevatron instantaneous luminosity increases, the limitation due to the simple algorithm starts to become clear. In this paper, we will present an upgrade path to the level-2 calorimeter trigger system at CDF. This upgrade approach is based on the Pulsar board, a general purpose VME board developed at CDF and used for upgrading both the level-2 tracking and the Level-2 global decision crate. This paper will describe the design, hardware and software implementation, as well as the advantages of this approach over the existing system.","PeriodicalId":217483,"journal":{"name":"2007 15th IEEE-NPSS Real-Time Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 15th IEEE-NPSS Real-Time Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/nssmic.2006.354160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The CDF Run II level-2 calorimeter trigger is implemented in hardware and is based on a simple algorithm used in Run I. This system has worked well for Run II at low luminosity. However, as the Tevatron instantaneous luminosity increases, the limitation due to the simple algorithm starts to become clear. In this paper, we will present an upgrade path to the level-2 calorimeter trigger system at CDF. This upgrade approach is based on the Pulsar board, a general purpose VME board developed at CDF and used for upgrading both the level-2 tracking and the Level-2 global decision crate. This paper will describe the design, hardware and software implementation, as well as the advantages of this approach over the existing system.
CDF升级二级热量计触发器
CDF Run II 2级量热计触发器在硬件上实现,并基于Run i中使用的简单算法,该系统在低亮度下运行良好。然而,随着Tevatron瞬时光度的增加,由于简单算法的限制开始变得清晰。在本文中,我们将介绍CDF的二级热量计触发系统的升级路径。这种升级方法基于脉冲星板,脉冲星板是CDF开发的通用VME板,用于升级2级跟踪和2级全局决策箱。本文将介绍该系统的设计、硬件和软件实现,以及该方法相对于现有系统的优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信