{"title":"Noise detection on the low voltage network PLC channel for direct and indirect connections","authors":"A. Emleh, A. D. de Beer, H. Ferreira, A. Vinck","doi":"10.1109/MELCON.2014.6820532","DOIUrl":null,"url":null,"abstract":"The power-line communications channel (PLC) is one of the harsh and challenging channels due to heavy load and noise impairments. Sending and/or receiving of data bits over the PLC channel can be easily affected; therefore, several investigations have been conducted to illustrate interference effects over PLC where intermittent noise plays a major role in this type of communications channel. The in-building network is a non-stable system due to the heavy traffic in the wiring system; therefore the power-line communication system gets affected by the internal and external communications factors. In this paper we apply direct connections to the PLC networks in a “unique” method when the 220V mains are on and when off. Indirect connections are also conducted using different types of equipment and connections and results are presented.","PeriodicalId":103316,"journal":{"name":"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.2014.6820532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The power-line communications channel (PLC) is one of the harsh and challenging channels due to heavy load and noise impairments. Sending and/or receiving of data bits over the PLC channel can be easily affected; therefore, several investigations have been conducted to illustrate interference effects over PLC where intermittent noise plays a major role in this type of communications channel. The in-building network is a non-stable system due to the heavy traffic in the wiring system; therefore the power-line communication system gets affected by the internal and external communications factors. In this paper we apply direct connections to the PLC networks in a “unique” method when the 220V mains are on and when off. Indirect connections are also conducted using different types of equipment and connections and results are presented.