Absolute Temperature Thermal Mapping Methodology for Tester Applications

B. Lai, N. Leslie, P. Sabbineni, V. Ravikumar
{"title":"Absolute Temperature Thermal Mapping Methodology for Tester Applications","authors":"B. Lai, N. Leslie, P. Sabbineni, V. Ravikumar","doi":"10.31399/asm.cp.istfa2022p0120","DOIUrl":null,"url":null,"abstract":"\n Infrared lock-in thermography systems are frequently utilized for non-destructive failure analysis of integrated circuits due to sensitivity of the thermal detector to small temperature changes from electrical activity. This thermal sensitivity can also be leveraged for design verification and debug of device thermal management via absolute temperature mapping. The application of temperature mapping to a device under test (DUT) that requires boards and sockets, such as in tester based applications, has traditionally been challenging, due to the requirement that the DUT not be moved and the difficulty of heating the DUT through the thermal mass of the boards and sockets to which the DUT is mounted. This paper describes a proposed alternative single-temperature in-situ calibration method to eliminate the need for a heated thermal chuck for absolute temperature mapping. Preliminary results are promising and show that the new alternative single-temperature in-situ method results in temperature measurements within 1 °C close to room temperature and within 2.5 °C at elevated temperatures up to approximately 75 °C, as compared to the 1 °C accuracy of the current standard two-temperature in-situ method. While this alternate method is not as accurate as the standard two-temperature in-situ calibration method, the fact that it can be performed at a single room temperature means that it enables absolute temperature mapping for use cases requiring boards or socketed DUTs, as is the case for tester applications. An example characterization of a DUT utilizing varying clock signal inputs shows the added flexibility and ease of setup that the alternative single-temperature workflow brings, creating new opportunities for use-cases such as boards and testers where the use of a heated thermal chuck is not viable.","PeriodicalId":417175,"journal":{"name":"International Symposium for Testing and Failure Analysis","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium for Testing and Failure Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.cp.istfa2022p0120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Infrared lock-in thermography systems are frequently utilized for non-destructive failure analysis of integrated circuits due to sensitivity of the thermal detector to small temperature changes from electrical activity. This thermal sensitivity can also be leveraged for design verification and debug of device thermal management via absolute temperature mapping. The application of temperature mapping to a device under test (DUT) that requires boards and sockets, such as in tester based applications, has traditionally been challenging, due to the requirement that the DUT not be moved and the difficulty of heating the DUT through the thermal mass of the boards and sockets to which the DUT is mounted. This paper describes a proposed alternative single-temperature in-situ calibration method to eliminate the need for a heated thermal chuck for absolute temperature mapping. Preliminary results are promising and show that the new alternative single-temperature in-situ method results in temperature measurements within 1 °C close to room temperature and within 2.5 °C at elevated temperatures up to approximately 75 °C, as compared to the 1 °C accuracy of the current standard two-temperature in-situ method. While this alternate method is not as accurate as the standard two-temperature in-situ calibration method, the fact that it can be performed at a single room temperature means that it enables absolute temperature mapping for use cases requiring boards or socketed DUTs, as is the case for tester applications. An example characterization of a DUT utilizing varying clock signal inputs shows the added flexibility and ease of setup that the alternative single-temperature workflow brings, creating new opportunities for use-cases such as boards and testers where the use of a heated thermal chuck is not viable.
测试应用的绝对温度热测绘方法
红外锁定热成像系统经常用于集成电路的非破坏性故障分析,因为热探测器对电活动引起的微小温度变化非常敏感。这种热敏性也可以通过绝对温度映射用于器件热管理的设计验证和调试。将温度映射应用于需要电路板和插座的被测设备(DUT),例如在基于测试仪的应用中,传统上一直具有挑战性,因为要求不能移动被测设备,并且很难通过安装被测设备的电路板和插座的热质量加热被测设备。本文介绍了一种备选的单温度原位校准方法,以消除对加热热卡盘进行绝对温度测绘的需要。初步结果是有希望的,并且表明新的替代单温度原位方法可以在接近室温的1°C范围内测量温度,在高达约75°C的高温下在2.5°C范围内测量温度,而目前标准双温度原位方法的精度为1°C。虽然这种替代方法不如标准的双温度原位校准方法准确,但它可以在单个室温下执行的事实意味着它可以为需要电路板或插入式dut的用例提供绝对温度映射,就像测试仪应用的情况一样。使用不同时钟信号输入的DUT的一个示例特性显示了可选的单温度工作流程带来的额外的灵活性和设置的便捷性,为使用加热热卡盘不可行的电路板和测试器等用例创造了新的机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信