The Influence of Washing Cycles on the Conductive Threads Used in E-textiles

Kateřina Rostás, J. Navrátil, R. Soukup, Daniela Moravcova
{"title":"The Influence of Washing Cycles on the Conductive Threads Used in E-textiles","authors":"Kateřina Rostás, J. Navrátil, R. Soukup, Daniela Moravcova","doi":"10.1109/ISSE54558.2022.9812770","DOIUrl":null,"url":null,"abstract":"E-textiles and smart textiles have already reached a certain stage of development. Nowadays, smart textiles designed for medicine or sports have been developed to be worn directly on the body, just like conventional textiles. This is the reason, why e-textiles and smart textiles should be able to withstand mechanical and chemical stresses during washing cycles. It is therefore essential to focus on their durability through repeated wash cycles. This paper focuses on the effect of washing cycles on the conductive fibers used in E-textiles. Two commercial conductive threads (Madeira HC12, SilverTech + 100) and two hybrid threads (T1, T2) were developed at the Faculty of electrical engineering at the University of West Bohemia and were selected for the experiment. The threads T1 and T2 consist of silver-plated copper microwires plied with PES multifilament threads. The commercial threads are based on silver-plated polyamide filaments. These filaments have an order of magnitude lower resistance than hybrid filaments. This paper investigates the change in electrical resistance of the four above-mentioned embroidered conductive threads due to their exposure to 30 washing cycles. The results of this experiment are presented in the paper, which shows that the coated commercial threads show better results after 30 wash cycles but are not suitable for all applications compared to the hybrid threads because of their higher electrical resistance. The wash resistance of hybrid threads can be increased by isolating individual microwires, which is not possible with plated yarns.","PeriodicalId":413385,"journal":{"name":"2022 45th International Spring Seminar on Electronics Technology (ISSE)","volume":"349 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 45th International Spring Seminar on Electronics Technology (ISSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSE54558.2022.9812770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

E-textiles and smart textiles have already reached a certain stage of development. Nowadays, smart textiles designed for medicine or sports have been developed to be worn directly on the body, just like conventional textiles. This is the reason, why e-textiles and smart textiles should be able to withstand mechanical and chemical stresses during washing cycles. It is therefore essential to focus on their durability through repeated wash cycles. This paper focuses on the effect of washing cycles on the conductive fibers used in E-textiles. Two commercial conductive threads (Madeira HC12, SilverTech + 100) and two hybrid threads (T1, T2) were developed at the Faculty of electrical engineering at the University of West Bohemia and were selected for the experiment. The threads T1 and T2 consist of silver-plated copper microwires plied with PES multifilament threads. The commercial threads are based on silver-plated polyamide filaments. These filaments have an order of magnitude lower resistance than hybrid filaments. This paper investigates the change in electrical resistance of the four above-mentioned embroidered conductive threads due to their exposure to 30 washing cycles. The results of this experiment are presented in the paper, which shows that the coated commercial threads show better results after 30 wash cycles but are not suitable for all applications compared to the hybrid threads because of their higher electrical resistance. The wash resistance of hybrid threads can be increased by isolating individual microwires, which is not possible with plated yarns.
洗涤次数对电子纺织品导电线的影响
电子纺织品和智能纺织品已经达到了一定的发展阶段。如今,为医疗或运动设计的智能纺织品已经被开发出来,可以像传统纺织品一样直接穿在身上。这就是为什么电子纺织品和智能纺织品应该能够在洗涤周期中承受机械和化学压力的原因。因此,必须通过反复洗涤循环来关注其耐久性。本文主要研究了洗涤次数对电子纺织品中导电纤维性能的影响。西波西米亚大学电气工程学院开发了两种商用导电线(Madeira HC12, SilverTech + 100)和两种混合导电线(T1, T2),并选择它们进行实验。螺纹T1和T2由镀银铜微细线与PES多丝线叠接而成。商业线是基于镀银聚酰胺长丝。这些细丝的电阻比杂交细丝低一个数量级。本文研究了上述四种绣花导电线经过30次洗涤后的电阻变化。实验结果表明,经过30次洗涤循环后,涂覆的商业螺纹表现出更好的效果,但与混合螺纹相比,由于其更高的电阻,因此并不适用于所有应用。通过隔离单个微丝,可以提高混合线的耐洗性,这是镀丝所不能做到的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信