{"title":"Transient Simulation of Single-Phase Synchronous Generators from Manufacturer Data","authors":"S. Neusues, N. Erd, A. Binder, G. Traxler-Samek","doi":"10.1109/SPEEDAM48782.2020.9161833","DOIUrl":null,"url":null,"abstract":"The parameters of a single-phase synchronous generator given as single-phase per-unit values from manufacturer data are converted into three-phase per-unit values. The parameter calculation is exemplified here for the manufacturer data of a typical single-phase generator. Based on these parameters and the dynamic equations in the d-q-rotor reference frame, a dynamic model is derived. In contrast to the dynamic models of commercially available software, the damper currents are given as output values. The transient single-phase sudden short-circuit current of a 40 kVA three-phase synchronous generator is numerically calculated with the presented dynamic model and compared with the analytical solution and measurement resuls.","PeriodicalId":207935,"journal":{"name":"2020 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM48782.2020.9161833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The parameters of a single-phase synchronous generator given as single-phase per-unit values from manufacturer data are converted into three-phase per-unit values. The parameter calculation is exemplified here for the manufacturer data of a typical single-phase generator. Based on these parameters and the dynamic equations in the d-q-rotor reference frame, a dynamic model is derived. In contrast to the dynamic models of commercially available software, the damper currents are given as output values. The transient single-phase sudden short-circuit current of a 40 kVA three-phase synchronous generator is numerically calculated with the presented dynamic model and compared with the analytical solution and measurement resuls.