Dielectric barrier discharge plasma reactor analysis as ozone generator

M. Nur, M. Restiwijaya, Tri A. Winarni
{"title":"Dielectric barrier discharge plasma reactor analysis as ozone generator","authors":"M. Nur, M. Restiwijaya, Tri A. Winarni","doi":"10.1109/ISTMET.2014.6936492","DOIUrl":null,"url":null,"abstract":"Ozone generator by using dielectric barrier discharge plasma (DBDP) has been studied. DBDP reactor was constructed with spiral cylender configuration. We found that ozone concentration increased with increasing of voltage, number of spools coil. The ozone concentration decreases with increasing distance between spiral electrode and cylender electrode. We found something very interesting in the generation of ozone, where electrc current has been measured, in other words ionization has occurred, but ozone was not formed. It can be interpreted that although ionization has occurred but oxygen molecular dissociation has not happened or is not enough for the formation of ozone.","PeriodicalId":364834,"journal":{"name":"2014 International Symposium on Technology Management and Emerging Technologies","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Technology Management and Emerging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISTMET.2014.6936492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Ozone generator by using dielectric barrier discharge plasma (DBDP) has been studied. DBDP reactor was constructed with spiral cylender configuration. We found that ozone concentration increased with increasing of voltage, number of spools coil. The ozone concentration decreases with increasing distance between spiral electrode and cylender electrode. We found something very interesting in the generation of ozone, where electrc current has been measured, in other words ionization has occurred, but ozone was not formed. It can be interpreted that although ionization has occurred but oxygen molecular dissociation has not happened or is not enough for the formation of ozone.
介质阻挡放电等离子体反应器作为臭氧发生器的分析
研究了介质阻挡放电等离子体(DBDP)臭氧发生器。采用螺旋圆筒结构构造DBDP反应器。结果表明,臭氧浓度随电压、线圈数的增加而增加。臭氧浓度随螺旋电极与圆柱电极间距的增大而减小。我们在臭氧的产生中发现了一些非常有趣的东西,在测量电流的地方,换句话说,电离发生了,但臭氧没有形成。这可以解释为虽然电离发生了,但氧分子解离没有发生或不足以形成臭氧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信