{"title":"Seismic Retrofit of Beam-to-Column Joints with Grouted Steel Tubes","authors":"T. E. Hoffschild, H. Prion, S. Cherry","doi":"10.14359/986","DOIUrl":null,"url":null,"abstract":"This paper presents the findings of an experimental study to evaluate a method of retrofit which addresses a particular weakness that is often found in reinforced concrete structures, especially older structures, namely the lack of sufficient reinforcement in and around beam-to-column joints. Many of these structures lack the required confining reinforcement within the joints and in adjoining beams and columns. The result is a reinforced concrete frame that is weak in the joint areas and lacks sufficient ductility during a seismic event. The proposed retrofit method consists of encasing the reinforced concrete joint with a grouted steel jacket that provides confinement to the joint area, and imparts ductility to the frame. In this study, two styles of retrofit jacket were tested: a circular steel tube and a rectangular casing. The two jacket styles are evaluated for strength, stiffness and ductility, and their relative merits are discussed.","PeriodicalId":305630,"journal":{"name":"SP-157: Recent Developments In Lateral Force Transfer In Buildings","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-157: Recent Developments In Lateral Force Transfer In Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/986","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
This paper presents the findings of an experimental study to evaluate a method of retrofit which addresses a particular weakness that is often found in reinforced concrete structures, especially older structures, namely the lack of sufficient reinforcement in and around beam-to-column joints. Many of these structures lack the required confining reinforcement within the joints and in adjoining beams and columns. The result is a reinforced concrete frame that is weak in the joint areas and lacks sufficient ductility during a seismic event. The proposed retrofit method consists of encasing the reinforced concrete joint with a grouted steel jacket that provides confinement to the joint area, and imparts ductility to the frame. In this study, two styles of retrofit jacket were tested: a circular steel tube and a rectangular casing. The two jacket styles are evaluated for strength, stiffness and ductility, and their relative merits are discussed.