RESEARCH OF LONG-TERM DRIFT OF THE NATIONAL INDUCTANCE STANDARD

O. Velychko, Maxym Dombrovskyi
{"title":"RESEARCH OF LONG-TERM DRIFT OF THE NATIONAL INDUCTANCE STANDARD","authors":"O. Velychko, Maxym Dombrovskyi","doi":"10.23939/istcmtm2023.02.023","DOIUrl":null,"url":null,"abstract":"Inductance measurements is important for all branches of technology related to the application of electricity: energy and electronics, radio and television, transport and communication, and scientific research. Electromechanical devices and electronic components can be characterized using impedance measurements to identify the parameters of their equivalent electrical model. New inductance measurement methods are being developed in specific fields of activity. Manufacturers of standards and measuring instruments of inductance develop special handbooks outlining various methods of inductance measurement. The State Primary Standard of Ukraine for inductance and loss angle tangent reproduces and transmits a unit of inductance in the range from 1∙10-6 H to 10 H at a frequency of 1 kHz. It is keeping in the SE “Ukrmetrteststandard” and participated in several comparisons of national standards within the framework of the activities of regional metrological organizations. The calibration and measurement capabilities of inductance measurement of national laboratories of different countries were studied to analyze and compare the capabilities of the national standard with the standards of other countries. Long-term instability studies of inductance measures of 1 mH, 10 mH and 100 mH, which are part of the national standard unit of inductance, have been conducted. The research period covered from 2009 to 2022. It was established that the drift lines of the specified inductance measures can be described using linear approximations. The rationale for choosing inductance measures of 10 mH and 100 mH for their use as transmission standards in the calibration of standards, which were organized and conducted by SE “Ukrmetrteststandard” as their pilot laboratory, is given.","PeriodicalId":415989,"journal":{"name":"Measuring Equipment and Metrology","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measuring Equipment and Metrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23939/istcmtm2023.02.023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Inductance measurements is important for all branches of technology related to the application of electricity: energy and electronics, radio and television, transport and communication, and scientific research. Electromechanical devices and electronic components can be characterized using impedance measurements to identify the parameters of their equivalent electrical model. New inductance measurement methods are being developed in specific fields of activity. Manufacturers of standards and measuring instruments of inductance develop special handbooks outlining various methods of inductance measurement. The State Primary Standard of Ukraine for inductance and loss angle tangent reproduces and transmits a unit of inductance in the range from 1∙10-6 H to 10 H at a frequency of 1 kHz. It is keeping in the SE “Ukrmetrteststandard” and participated in several comparisons of national standards within the framework of the activities of regional metrological organizations. The calibration and measurement capabilities of inductance measurement of national laboratories of different countries were studied to analyze and compare the capabilities of the national standard with the standards of other countries. Long-term instability studies of inductance measures of 1 mH, 10 mH and 100 mH, which are part of the national standard unit of inductance, have been conducted. The research period covered from 2009 to 2022. It was established that the drift lines of the specified inductance measures can be described using linear approximations. The rationale for choosing inductance measures of 10 mH and 100 mH for their use as transmission standards in the calibration of standards, which were organized and conducted by SE “Ukrmetrteststandard” as their pilot laboratory, is given.
国家电感标准长期漂移的研究
电感测量对于与电力应用相关的所有技术分支都很重要:能源和电子、广播和电视、运输和通信以及科学研究。机电设备和电子元件可以使用阻抗测量来确定其等效电模型的参数。在特定的活动领域,新的电感测量方法正在发展。电感标准和测量仪器的制造商开发了专门的手册,概述了各种电感测量方法。乌克兰的电感和损耗角正切国家初级标准以1khz的频率再现和传输1∙10-6 H至10 H范围内的电感单位。它保持在东南欧的“乌克兰计量标准”,并参与了几次区域计量组织活动框架内的国家标准比较。研究了各国国家实验室电感测量的校准和测量能力,分析比较了国家标准与其他国家标准的校准和测量能力。对国家电感标准单位1mh、10mh、100mh的电感量进行了长期不稳定性研究。研究期间为2009年至2022年。建立了特定电感量的漂移线可以用线性近似来描述。介绍了在“乌克兰计量测试标准”试点实验室组织开展的标准校准工作中,选择10mh和100mh电感量作为传输标准的基本原理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信