SIMULASI PELIMPAHAN BEBAN SISTEM PMT KOPEL TO KOPEL PADA SAAT PEMELIHARAAN TRAFO BERBASIS ARDUINO MEGA 2560 MENGGUNAKAN VT SCADA 11.2

Muhammad Rizki Samputro, Arkhan Subari
{"title":"SIMULASI PELIMPAHAN BEBAN SISTEM PMT KOPEL TO KOPEL PADA SAAT PEMELIHARAAN TRAFO BERBASIS ARDUINO MEGA 2560 MENGGUNAKAN VT SCADA 11.2","authors":"Muhammad Rizki Samputro, Arkhan Subari","doi":"10.14710/gt.v20i3.25749","DOIUrl":null,"url":null,"abstract":"Mochammad Rizki Samputro, Arkhan Subari in this paper explains that the need for electricity in everyday life demands PT. PLN to always maintain the distribution of electrical energy to customers. Therefore, it is necessary to use a strategy to prevent blackouts if the transformer is being maintained, that is by maneuvering the load through the network or by using a 20 KV coupling system. The 20 KV Coupling System consists of PMT Kopel Transformer 1 and PMT Kopel Transformer 2 or often called PMT Kopel to Kopel. In this research, a Kopel to Kopel PMT simulation tool is used to transfer transformer loads during maintenance using a LY2N DPDT 12 V relay, ZMCT103C current transformer sensor, voltage sensor, tap changer and use Arduino Mega 2560 as a delivery choice change. After the experiment, the total current size of transformer 1 and transformer 2 exceeds the capacity of transformer which is 4.29 A and the voltage difference is 0.71 V (5.9 %). Therefore it is necessary to adjust the current and voltage regulation so that it becomes 2.82 A and 0.06 V (0.5 %). After that the transfer of load Transformer 2 to Transformer 1 using PMT Kopel to Kopel can be done. The load transfer is done by entering the PMT Kopel 1 and PMT Kopel 2 simultaneously and the Incoming 2 PMT is released. For the normalization, PMT Incoming 2 is entered and PMT Kopel 1 and Kopel 2 are released simultaneously.","PeriodicalId":362808,"journal":{"name":"Gema Teknologi","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gema Teknologi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/gt.v20i3.25749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Mochammad Rizki Samputro, Arkhan Subari in this paper explains that the need for electricity in everyday life demands PT. PLN to always maintain the distribution of electrical energy to customers. Therefore, it is necessary to use a strategy to prevent blackouts if the transformer is being maintained, that is by maneuvering the load through the network or by using a 20 KV coupling system. The 20 KV Coupling System consists of PMT Kopel Transformer 1 and PMT Kopel Transformer 2 or often called PMT Kopel to Kopel. In this research, a Kopel to Kopel PMT simulation tool is used to transfer transformer loads during maintenance using a LY2N DPDT 12 V relay, ZMCT103C current transformer sensor, voltage sensor, tap changer and use Arduino Mega 2560 as a delivery choice change. After the experiment, the total current size of transformer 1 and transformer 2 exceeds the capacity of transformer which is 4.29 A and the voltage difference is 0.71 V (5.9 %). Therefore it is necessary to adjust the current and voltage regulation so that it becomes 2.82 A and 0.06 V (0.5 %). After that the transfer of load Transformer 2 to Transformer 1 using PMT Kopel to Kopel can be done. The load transfer is done by entering the PMT Kopel 1 and PMT Kopel 2 simultaneously and the Incoming 2 PMT is released. For the normalization, PMT Incoming 2 is entered and PMT Kopel 1 and Kopel 2 are released simultaneously.
mohammad Rizki Samputro, Arkhan Subari在论文中解释了日常生活中对电力的需求要求PT. PLN始终保持向客户分配电能。因此,有必要使用一种策略来防止停电,如果变压器正在维护,即通过网络操纵负载或使用20kv耦合系统。20kv耦合系统由PMT科佩尔变压器1和PMT科佩尔变压器2或通常称为PMT科佩尔到科佩尔。在本研究中,使用Kopel to Kopel PMT仿真工具在维护期间使用LY2N DPDT 12v继电器,ZMCT103C电流互感器传感器,电压传感器,分接开关传递变压器负载,并使用Arduino Mega 2560作为交付选择更改。经过实验,变压器1和变压器2的总电流大小超过变压器容量4.29 A,电压差为0.71 V(5.9%)。因此,有必要调整电流和电压调节,使其成为2.82 A和0.06 V(0.5%)。之后,可以使用PMT Kopel到Kopel将负载变压器2转移到变压器1。通过同时进入PMT Kopel 1和PMT Kopel 2来完成负载转移,并释放传入的2 PMT。为了标准化,输入PMT Incoming 2,同时释放PMT Kopel 1和Kopel 2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信