{"title":"A DC model for transient analysis of a series active filter integrated with a double-series diode rectifier","authors":"S. Srianthumrong, H. Akagi","doi":"10.1109/PCC.2002.998516","DOIUrl":null,"url":null,"abstract":"This paper proposes a DC model of a series active filter integrated with a double-series diode rectifier. The model is developed with the help of the d-q coordinates transformation. It can be used to accurately and simply analyze transient characteristics of the integrated system around the fundamental frequency, instead of analyzing a complex AC-DC system taking into account the behavior of switching devices. The analysis makes the following assumptions: the system is balanced, and the three-phase supply currents are continuous; supply current harmonics in the integrated system are not so large as to affect the transient characteristics; and the DC load is resistive. The analysis using the DC model tells us that either increasing the active filter gain or decreasing the cut-off frequency of the harmonic detector results in a slow response, and causes a large and long transient of the DC voltage. Simulation results using the EMTDC software package verify the validity of the proposed DC model.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCC.2002.998516","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This paper proposes a DC model of a series active filter integrated with a double-series diode rectifier. The model is developed with the help of the d-q coordinates transformation. It can be used to accurately and simply analyze transient characteristics of the integrated system around the fundamental frequency, instead of analyzing a complex AC-DC system taking into account the behavior of switching devices. The analysis makes the following assumptions: the system is balanced, and the three-phase supply currents are continuous; supply current harmonics in the integrated system are not so large as to affect the transient characteristics; and the DC load is resistive. The analysis using the DC model tells us that either increasing the active filter gain or decreasing the cut-off frequency of the harmonic detector results in a slow response, and causes a large and long transient of the DC voltage. Simulation results using the EMTDC software package verify the validity of the proposed DC model.