The Preliminary Analysis of the Effect of Low-Energy Plasma Treatment on Internal Stresses in a Welded Plate of Steel S355

D. Nowak, G. Chruścielski, A. Ambroziak, I. Elkin
{"title":"The Preliminary Analysis of the Effect of Low-Energy Plasma Treatment on Internal Stresses in a Welded Plate of Steel S355","authors":"D. Nowak, G. Chruścielski, A. Ambroziak, I. Elkin","doi":"10.17729/ebis.2020.4/5","DOIUrl":null,"url":null,"abstract":"The articles presents a pilot study aimed to provide preliminary assessment concerning the effect of the low-energy plasma treatment on the level of internal stresses in welded plates. In addition, the article discusses the similarity of a stress relief mechanism based on annealing and that based on low-energy plasma treatment. The extensormetric measurements of internal stresses involving steel S355 after welding and after treatment in the plasma chamber revealed the low-energy plasma treatment-induced reduction of internal stresses.","PeriodicalId":184101,"journal":{"name":"Biuletyn Instytutu Spawalnictwa","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biuletyn Instytutu Spawalnictwa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17729/ebis.2020.4/5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The articles presents a pilot study aimed to provide preliminary assessment concerning the effect of the low-energy plasma treatment on the level of internal stresses in welded plates. In addition, the article discusses the similarity of a stress relief mechanism based on annealing and that based on low-energy plasma treatment. The extensormetric measurements of internal stresses involving steel S355 after welding and after treatment in the plasma chamber revealed the low-energy plasma treatment-induced reduction of internal stresses.
低能等离子体处理对S355钢焊接板内应力影响的初步分析
本文提出了一项初步研究,旨在初步评估低能等离子体处理对焊接板内应力水平的影响。此外,本文还讨论了基于退火和基于低能等离子体处理的应力消除机制的相似性。对S355钢焊接后和等离子体室处理后的内应力进行了拉伸测量,结果表明低能等离子体处理导致内应力降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信