{"title":"The Thermal Image of Sun Orientation and Openings in Residential Buildings with Modern Tropical Design Concept in Medan City","authors":"Harry Wibowo, Dicky Andrea, Sembiring","doi":"10.32734/koridor.v14i1.11893","DOIUrl":null,"url":null,"abstract":"This study aims to analyze thermal imagery of the sun's orientation and the formation of openings in residential houses with a modern tropical design concept in Medan. The method used is temperature measurement and building thermal identification using a digital thermal imaging tool, namely Flir CX-3, which is carried out during the day, as well as measuring the WWR (window-to-wall ratio) value of the building. The results of the thermal image analysis show that the North-South orientation gets lower temperatures compared to the East-West orientation, even though it has a larger WWR value of 12.9% and 20.9%. Based on the results of this analysis, it is suggested to consider the orientation of the sun in designing residential houses in the city of Medan. Houses with a North-South orientation are the best choice for maximum thermal comfort and natural lighting, supported by large openings as one of the characteristics of modern tropical architecture.","PeriodicalId":447776,"journal":{"name":"Jurnal Koridor","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Koridor","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32734/koridor.v14i1.11893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study aims to analyze thermal imagery of the sun's orientation and the formation of openings in residential houses with a modern tropical design concept in Medan. The method used is temperature measurement and building thermal identification using a digital thermal imaging tool, namely Flir CX-3, which is carried out during the day, as well as measuring the WWR (window-to-wall ratio) value of the building. The results of the thermal image analysis show that the North-South orientation gets lower temperatures compared to the East-West orientation, even though it has a larger WWR value of 12.9% and 20.9%. Based on the results of this analysis, it is suggested to consider the orientation of the sun in designing residential houses in the city of Medan. Houses with a North-South orientation are the best choice for maximum thermal comfort and natural lighting, supported by large openings as one of the characteristics of modern tropical architecture.