H. Chien, Ming-Hsi Tseng, Chih-Yao Wang, Chu Chun-Hsun
{"title":"The study of micro-fin heat sinks for electronic cooling applications","authors":"H. Chien, Ming-Hsi Tseng, Chih-Yao Wang, Chu Chun-Hsun","doi":"10.1109/STHERM.2001.915181","DOIUrl":null,"url":null,"abstract":"A variety of pin fin parameters were studied and tested to calculate an empirical relationship which can predict the optimum thermal performance of the micro pin fin structure. The sample parameters tested are as follows: (1) fin size from 0.2 mm to 1.0 mm; (2) fin height from 2.0 mm to 10.0 mm. The errors from comparison of the empirical relationship with the test data are less than 5%, so we can use this empirical relationship to estimate the optimum performance of pin fin heat sinks. According to the results from empirical relationship, the ratio of optimum fin pitch to fin size (fin pitch/fin size) is about 1.5/spl sim/1.7. Greater fin height gives higher thermal performance, and a smaller fin size structure has the potential for better thermal performance than huge fin size structures.","PeriodicalId":307079,"journal":{"name":"Seventeenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.01CH37189)","volume":"333 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seventeenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.01CH37189)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STHERM.2001.915181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
A variety of pin fin parameters were studied and tested to calculate an empirical relationship which can predict the optimum thermal performance of the micro pin fin structure. The sample parameters tested are as follows: (1) fin size from 0.2 mm to 1.0 mm; (2) fin height from 2.0 mm to 10.0 mm. The errors from comparison of the empirical relationship with the test data are less than 5%, so we can use this empirical relationship to estimate the optimum performance of pin fin heat sinks. According to the results from empirical relationship, the ratio of optimum fin pitch to fin size (fin pitch/fin size) is about 1.5/spl sim/1.7. Greater fin height gives higher thermal performance, and a smaller fin size structure has the potential for better thermal performance than huge fin size structures.
研究并测试了各种钉片参数,计算出了预测微型钉片结构最佳热性能的经验关系。试验样品参数如下:(1)翅片尺寸为0.2 mm ~ 1.0 mm;(2)翅片高度2.0 mm ~ 10.0 mm。经验关系式与试验数据的对比误差小于5%,因此可以利用该经验关系式对引脚翅片散热器的最佳性能进行估计。根据经验关系式的结果,最佳鳍距与鳍尺寸之比(鳍距/鳍尺寸)约为1.5/spl sim/1.7。较大的翅片高度具有较高的热性能,较小的翅片尺寸结构具有比巨大的翅片尺寸结构更好的热性能的潜力。