The impact of 50 Hz railroad systems on utility system unbalance

P. Heine, M. Hyvarinen, J. Niskanen, A. Oikarinen, H. Renner, M. Lehtonen
{"title":"The impact of 50 Hz railroad systems on utility system unbalance","authors":"P. Heine, M. Hyvarinen, J. Niskanen, A. Oikarinen, H. Renner, M. Lehtonen","doi":"10.1109/PQ.2010.5550017","DOIUrl":null,"url":null,"abstract":"50 Hz railway loads, typically supplied by two phases of the transmission system, represent a possible source of the unbalance. The penetration of the unbalance is highly dependent on the stiffness of the power system and connections from the local, public network. This paper presents observations of the unbalance caused by rail loads in two various Finnish areas. Kainuu represents a rural area of a relatively weak transmission system and heavy ore trains. On the opposite, Helsinki urban area has a stiff transmission system and train loads are proportionally considerably minor. These extreme Finnish power system characteristics result in relatively high unbalance values in Kainuu and lower values in Helsinki.","PeriodicalId":356169,"journal":{"name":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2010 Electric Power Quality and Supply Reliability Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2010.5550017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

50 Hz railway loads, typically supplied by two phases of the transmission system, represent a possible source of the unbalance. The penetration of the unbalance is highly dependent on the stiffness of the power system and connections from the local, public network. This paper presents observations of the unbalance caused by rail loads in two various Finnish areas. Kainuu represents a rural area of a relatively weak transmission system and heavy ore trains. On the opposite, Helsinki urban area has a stiff transmission system and train loads are proportionally considerably minor. These extreme Finnish power system characteristics result in relatively high unbalance values in Kainuu and lower values in Helsinki.
50赫兹铁路系统对公用事业系统不平衡的影响
50赫兹的铁路负荷,通常由两相传输系统提供,代表了不平衡的可能来源。不平衡的渗透在很大程度上取决于电力系统的刚度和本地、公共网络的连接。本文介绍了芬兰两个不同地区铁路负荷引起的不平衡现象。凯努代表了一个传输系统相对较弱和重型矿石列车的农村地区。相反,赫尔辛基市区有一个僵硬的传输系统,火车的负荷比例相当小。这些极端的芬兰电力系统特性导致凯努的不平衡值相对较高,而赫尔辛基的不平衡值相对较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信