{"title":"Sensitivity of ultrasound in the detection of biliary tract obstruction.","authors":"W A Winter,&nbsp;M R Esseveld,&nbsp;P Warners,&nbsp;E Frensdorff,&nbsp;Y T King,&nbsp;H Kruiswijk,&nbsp;W P Verdegaal","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In 28 patient with varying degrees of biliary obstruction, the ultrasonic findings were correlated with the serum bilirubin levels and with the size of the bile ducts as measured by percutaneous transhepatic cholangiography (PTC). With ultrasound, study of the intrahepatic ducts achieved the greatest accuracy (71%); examination of common bile ducts and the gallbladder were found to be less sensitive (54 and 53%). Ultrasound proved to be very accurate in biliary obstruction, when the serum bilirubin was above 4.8 mg/100 ml (80 mumol/1).</p>","PeriodicalId":76405,"journal":{"name":"Radiologia clinica","volume":"47 5","pages":"321-9"},"PeriodicalIF":0.0000,"publicationDate":"1978-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia clinica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In 28 patient with varying degrees of biliary obstruction, the ultrasonic findings were correlated with the serum bilirubin levels and with the size of the bile ducts as measured by percutaneous transhepatic cholangiography (PTC). With ultrasound, study of the intrahepatic ducts achieved the greatest accuracy (71%); examination of common bile ducts and the gallbladder were found to be less sensitive (54 and 53%). Ultrasound proved to be very accurate in biliary obstruction, when the serum bilirubin was above 4.8 mg/100 ml (80 mumol/1).

超声检测胆道梗阻的敏感性。
在28例不同程度胆道梗阻患者中,超声表现与血清胆红素水平及经皮经肝胆管造影(PTC)测量的胆管大小相关。超声检查肝内导管的准确率最高(71%);检查胆总管和胆囊时发现敏感度较低(分别为54%和53%)。当血清胆红素高于4.8 mg/100 ml (80 μ mol/1)时,超声诊断胆道梗阻非常准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信