{"title":"An analysis of the dosimetry for mantle field therapy using 4 MV X-rays and its routine application.","authors":"R Nair, D E Wrede, M Kartha, F Batley","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>There are several different methods in vogue at present in determining patient midplane doses in the \"mantle\" treatment for Hodgkin's disease and malignant lymphomas. A method of determining midplane doses in individual cases using thermoluminescent dosimetry is presented. It shows excellent agreement with the midplane doses measured in an Alderson-Rando phantom treated as a hypothetical \"mantle\" patient.</p>","PeriodicalId":76463,"journal":{"name":"Revista interamericana de radiologia","volume":"4 4","pages":"169-72"},"PeriodicalIF":0.0000,"publicationDate":"1979-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista interamericana de radiologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
There are several different methods in vogue at present in determining patient midplane doses in the "mantle" treatment for Hodgkin's disease and malignant lymphomas. A method of determining midplane doses in individual cases using thermoluminescent dosimetry is presented. It shows excellent agreement with the midplane doses measured in an Alderson-Rando phantom treated as a hypothetical "mantle" patient.