Jiazheng Lu, Chun Zhao, Bo Li, Zhen Fang, Hongxiang Zhang, Xiaochun Li
{"title":"Study and experiment of mobile DC de-icer for overhead ground wire","authors":"Jiazheng Lu, Chun Zhao, Bo Li, Zhen Fang, Hongxiang Zhang, Xiaochun Li","doi":"10.1109/ICSSEM.2012.6340743","DOIUrl":null,"url":null,"abstract":"Serious icing disasters threaten the safe running of power system. Overhead ground wires are difficult to de-ice with common heat de-icing methods in some special areas. A mobile DC de-icer for the overhead ground wire is developed in this paper to realize flexible de-icing. A diesel generator provides the 50 Hz three-phase power supply. A rectifier transformer is used to step up the voltage and a rectifier is used to convert AC to DC. The 12-pulse rectification mode is adopted to reduce the current harmonics of the rectifier and to decrease the ripple of the DC output. Onsite experiment of the mobile DC de-icer for the overhead ground wire is performed on a GJ-70 typed overhead ground wire with the length of 4847 meters. A temperature rise of 7.0°C is achieved in 36 minutes under the DC de-icing voltage of 2700 V and current of 100 A. The result shows that the mobile DC de-icer for overhead ground wire can operate reliably and can meet the demand of flexible de-icing.","PeriodicalId":115037,"journal":{"name":"2012 3rd International Conference on System Science, Engineering Design and Manufacturing Informatization","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd International Conference on System Science, Engineering Design and Manufacturing Informatization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSSEM.2012.6340743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Serious icing disasters threaten the safe running of power system. Overhead ground wires are difficult to de-ice with common heat de-icing methods in some special areas. A mobile DC de-icer for the overhead ground wire is developed in this paper to realize flexible de-icing. A diesel generator provides the 50 Hz three-phase power supply. A rectifier transformer is used to step up the voltage and a rectifier is used to convert AC to DC. The 12-pulse rectification mode is adopted to reduce the current harmonics of the rectifier and to decrease the ripple of the DC output. Onsite experiment of the mobile DC de-icer for the overhead ground wire is performed on a GJ-70 typed overhead ground wire with the length of 4847 meters. A temperature rise of 7.0°C is achieved in 36 minutes under the DC de-icing voltage of 2700 V and current of 100 A. The result shows that the mobile DC de-icer for overhead ground wire can operate reliably and can meet the demand of flexible de-icing.