{"title":"Preparation and Application Porous TiO2 for SO2 Gas Sensor","authors":"N. Syuhada, Brian Yulianto, Nugraha","doi":"10.2991/assehr.k.200220.025","DOIUrl":null,"url":null,"abstract":"—Air Pollution become one of serious issue that must be deal with. One of them is SO 2 Pollution. This gas is hazardous even in small concentration and can cause inflammation and irritation on respiratory system. Therefore, it is urgent to made an early detection device that can detect the existence and level of SO 2 concentration. This research was successful to find out the performance of TiO2 material for detection SO2 gas. SO 2 gas concentration used is 10 ppm. The TiO2 material was synthesized using solvothermal method at 180 C by varying the reaction time. Sensitive material is made above the FTO glass. The Material Characterization indicate the structure of TiO2 is rutile which have round structure that covered by nanorods TiO 2 . The size of the diameter of nanorods increases with increasing reaction time. Sensor testing was carried out from 150 o C – 350 o C using 10 ppm SO 2 . The test results showed that the best sensor response was obtained from samples with a reaction time of 12 hours at working temperature of 350 o C.","PeriodicalId":426548,"journal":{"name":"Proceedings of the 2nd International Conference on Islam, Science and Technology (ICONIST 2019)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Islam, Science and Technology (ICONIST 2019)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2991/assehr.k.200220.025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
—Air Pollution become one of serious issue that must be deal with. One of them is SO 2 Pollution. This gas is hazardous even in small concentration and can cause inflammation and irritation on respiratory system. Therefore, it is urgent to made an early detection device that can detect the existence and level of SO 2 concentration. This research was successful to find out the performance of TiO2 material for detection SO2 gas. SO 2 gas concentration used is 10 ppm. The TiO2 material was synthesized using solvothermal method at 180 C by varying the reaction time. Sensitive material is made above the FTO glass. The Material Characterization indicate the structure of TiO2 is rutile which have round structure that covered by nanorods TiO 2 . The size of the diameter of nanorods increases with increasing reaction time. Sensor testing was carried out from 150 o C – 350 o C using 10 ppm SO 2 . The test results showed that the best sensor response was obtained from samples with a reaction time of 12 hours at working temperature of 350 o C.