Preparation and Application Porous TiO2 for SO2 Gas Sensor

N. Syuhada, Brian Yulianto, Nugraha
{"title":"Preparation and Application Porous TiO2 for SO2 Gas Sensor","authors":"N. Syuhada, Brian Yulianto, Nugraha","doi":"10.2991/assehr.k.200220.025","DOIUrl":null,"url":null,"abstract":"—Air Pollution become one of serious issue that must be deal with. One of them is SO 2 Pollution. This gas is hazardous even in small concentration and can cause inflammation and irritation on respiratory system. Therefore, it is urgent to made an early detection device that can detect the existence and level of SO 2 concentration. This research was successful to find out the performance of TiO2 material for detection SO2 gas. SO 2 gas concentration used is 10 ppm. The TiO2 material was synthesized using solvothermal method at 180 C by varying the reaction time. Sensitive material is made above the FTO glass. The Material Characterization indicate the structure of TiO2 is rutile which have round structure that covered by nanorods TiO 2 . The size of the diameter of nanorods increases with increasing reaction time. Sensor testing was carried out from 150 o C – 350 o C using 10 ppm SO 2 . The test results showed that the best sensor response was obtained from samples with a reaction time of 12 hours at working temperature of 350 o C.","PeriodicalId":426548,"journal":{"name":"Proceedings of the 2nd International Conference on Islam, Science and Technology (ICONIST 2019)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Islam, Science and Technology (ICONIST 2019)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2991/assehr.k.200220.025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

—Air Pollution become one of serious issue that must be deal with. One of them is SO 2 Pollution. This gas is hazardous even in small concentration and can cause inflammation and irritation on respiratory system. Therefore, it is urgent to made an early detection device that can detect the existence and level of SO 2 concentration. This research was successful to find out the performance of TiO2 material for detection SO2 gas. SO 2 gas concentration used is 10 ppm. The TiO2 material was synthesized using solvothermal method at 180 C by varying the reaction time. Sensitive material is made above the FTO glass. The Material Characterization indicate the structure of TiO2 is rutile which have round structure that covered by nanorods TiO 2 . The size of the diameter of nanorods increases with increasing reaction time. Sensor testing was carried out from 150 o C – 350 o C using 10 ppm SO 2 . The test results showed that the best sensor response was obtained from samples with a reaction time of 12 hours at working temperature of 350 o C.
SO2气体传感器用多孔TiO2的制备及应用
空气污染已成为必须解决的严重问题之一。其中之一就是二氧化硫污染。这种气体即使浓度很小也有危险,会引起呼吸系统的炎症和刺激。因此,迫切需要研制一种能够检测出so2浓度存在及水平的早期检测装置。本研究成功地发现了TiO2材料检测SO2气体的性能。二氧化硫气体使用浓度为10ppm。通过改变反应时间,采用溶剂热法在180℃下合成TiO2材料。FTO玻璃上面是敏感材料。材料表征表明,TiO2为金红石型,呈圆形结构,被纳米TiO2覆盖。纳米棒的直径随反应时间的延长而增大。传感器测试在150°C - 350°C之间进行,使用10 ppm so2。测试结果表明,在350℃的工作温度下,反应时间为12小时的样品获得了最佳的传感器响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信