Examination of bacterial toxin measurement using Quartz crystal microbalance method

A. Tsuji, K. Ooe, N. Nishishita, Y. Hirano
{"title":"Examination of bacterial toxin measurement using Quartz crystal microbalance method","authors":"A. Tsuji, K. Ooe, N. Nishishita, Y. Hirano","doi":"10.1109/MHS.2007.4420860","DOIUrl":null,"url":null,"abstract":"When renal failure patients undergo the hemodialysis, the endtoxin (ET) that is the bacterial toxin that causes the symptom such as generation of heat is measured as one of the pollution markers. Presently, because the high performance filtration equipment develops, the amount of ET in dyalysate water and solution was achieved under the ET standard value set by Japanese Society for Dialysis Therapy etc. However, the ET measurement is obligated to the moon a couple of degrees at the dialysis center etc. the measurement is needed for 30 minutes or more since it use batch method and rely on the chemical reaction. In this study, we paid attention to the polyamino acid named epsiv-polylisine (epsiv-PL) that can select and adsorb ET and the mass measurement using quartz crystal microbalance method (QCM). We aim to the development of the real-time ET measuring system using these. If it is achieved, the amount of ET can be monitored while blood is dialyzed. Moreover, it seems that treatment that discontinues dialyzing can be taken when it exceeds the reference value.","PeriodicalId":161669,"journal":{"name":"2007 International Symposium on Micro-NanoMechatronics and Human Science","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Symposium on Micro-NanoMechatronics and Human Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MHS.2007.4420860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

When renal failure patients undergo the hemodialysis, the endtoxin (ET) that is the bacterial toxin that causes the symptom such as generation of heat is measured as one of the pollution markers. Presently, because the high performance filtration equipment develops, the amount of ET in dyalysate water and solution was achieved under the ET standard value set by Japanese Society for Dialysis Therapy etc. However, the ET measurement is obligated to the moon a couple of degrees at the dialysis center etc. the measurement is needed for 30 minutes or more since it use batch method and rely on the chemical reaction. In this study, we paid attention to the polyamino acid named epsiv-polylisine (epsiv-PL) that can select and adsorb ET and the mass measurement using quartz crystal microbalance method (QCM). We aim to the development of the real-time ET measuring system using these. If it is achieved, the amount of ET can be monitored while blood is dialyzed. Moreover, it seems that treatment that discontinues dialyzing can be taken when it exceeds the reference value.
石英晶体微天平法测定细菌毒素的检验
当肾功能衰竭患者进行血液透析时,内毒素(endtoxin, ET)是引起发热等症状的细菌毒素,作为污染指标之一进行测量。目前,由于高性能过滤设备的发展,透析水和溶液中的ET含量已达到日本透析治疗协会等制定的ET标准值。然而,ET测量必须在透析中心的月球几度等处进行,测量需要30分钟或更长时间,因为它使用批量方法并依赖于化学反应。在本研究中,我们关注了一种名为epsiv- polylinine (epsiv-PL)的聚氨基酸,它可以选择和吸附ET,并使用石英晶体微天平法(QCM)进行了质量测量。我们的目标是利用这些方法开发实时ET测量系统。如果达到这个目标,就可以在血液透析时监测ET的量。此外,当透析超过参考值时,似乎可以采取停止透析的治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信