Performance Evaluation of an Installed On-Grid Photovoltaic System at Bamako

Bakamba dite Djeneba Sacko, S. Sanogo, Abdramane Ba
{"title":"Performance Evaluation of an Installed On-Grid Photovoltaic System at Bamako","authors":"Bakamba dite Djeneba Sacko, S. Sanogo, Abdramane Ba","doi":"10.11648/j.epes.20231201.12","DOIUrl":null,"url":null,"abstract":": The primary goal of this paper is to analyze the performance of an installed on-grid photovoltaic 100 kW system installed on the roof of a building at the Institute of Applied Sciences, University of Sciences, Techniques and Technologies of Bamako. The system under consideration is part of a pilot project of a grid-connected system in Mali by the Renewable Energies Agency (AER). The PV system is located at 12.62°N latitude and -7.99°W longitude. It is composed of 313 monocrystalline modules of 320W for an installed power of approximately 101kWp and they are fixed on support inclined at 6 degrees orientated East-West. The system was monitored from March 2020 to February 2021. Within this period, the photovoltaic system supplied 114801.57 kWh to the grid with the final yield varying between 2.41 to 4.09 kWh/kWp/day. Additionally, the ratio of performance in this one year ranged from 53% to 89%. The annual capacity factor and efficiency are 13% and 10%, respectively. The main roots of this bad performance of the system are analyzed. The system performance is significantly affected by the soiling effects which are in other words attributed to meteorological and environmental parameters mainly dust accumulation and ambient temperature, as well as, factors like inclination (low tilt angle (6°)), the east and west orientation of the panels and finally lack of cleaning frequencies.","PeriodicalId":125088,"journal":{"name":"American Journal of Electrical Power and Energy Systems","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Electrical Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/j.epes.20231201.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: The primary goal of this paper is to analyze the performance of an installed on-grid photovoltaic 100 kW system installed on the roof of a building at the Institute of Applied Sciences, University of Sciences, Techniques and Technologies of Bamako. The system under consideration is part of a pilot project of a grid-connected system in Mali by the Renewable Energies Agency (AER). The PV system is located at 12.62°N latitude and -7.99°W longitude. It is composed of 313 monocrystalline modules of 320W for an installed power of approximately 101kWp and they are fixed on support inclined at 6 degrees orientated East-West. The system was monitored from March 2020 to February 2021. Within this period, the photovoltaic system supplied 114801.57 kWh to the grid with the final yield varying between 2.41 to 4.09 kWh/kWp/day. Additionally, the ratio of performance in this one year ranged from 53% to 89%. The annual capacity factor and efficiency are 13% and 10%, respectively. The main roots of this bad performance of the system are analyzed. The system performance is significantly affected by the soiling effects which are in other words attributed to meteorological and environmental parameters mainly dust accumulation and ambient temperature, as well as, factors like inclination (low tilt angle (6°)), the east and west orientation of the panels and finally lack of cleaning frequencies.
巴马科已安装并网光伏系统的性能评估
本文的主要目标是分析安装在巴马科科技大学应用科学研究所一座建筑物屋顶上的100千瓦并网光伏系统的性能。正在考虑的这个系统是可再生能源署(AER)在马里的一个并网系统试点项目的一部分。光伏系统位于北纬12.62°,西经-7.99°。它由313个320W单晶模块组成,装机功率约101kWp,固定在东西倾斜6度的支架上。该系统从2020年3月到2021年2月进行了监测。在此期间,光伏系统向电网供电114801.57 kWh,最终发电量在2.41 - 4.09 kWh/kWp/天之间变化。此外,这一年的绩效比率从53%到89%不等。年容量系数和效率分别为13%和10%。分析了系统性能不佳的主要原因。系统性能受污染影响显著,污染影响主要受气象和环境参数(主要是积尘量和环境温度)、倾角(低倾斜角(6°))、面板的东西朝向以及缺乏清洁频率等因素影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信