In vivo measurement of blood recirculation during "Y" type single needle dialysis.

D A Ogden
{"title":"In vivo measurement of blood recirculation during \"Y\" type single needle dialysis.","authors":"D A Ogden","doi":"10.3109/08860227909063945","DOIUrl":null,"url":null,"abstract":"<p><p>A method has been described and validated for obtaining a sample of blood, without separate venapuncture, which has the same urea and creatinine composition as systemic venous blood during hemodialysis. Using this technique, recirculation in vivo during \"Y\" type single needle dialysis, measured in 20 bovine fistulas, ranged from 6.9% to 56.5% and averaged 19.4% of blood flow rate as calculated from blood urea nitrogen; and averaged 22.0% with a range of 3.3% to 62.1% of blood flow rate as calculated from serum creatinine concentration. These results suggest that fistula puncture methods and devices that eliminate recirculation in the ex vivo blood circuit should be used to maximize dialysis efficiency.</p>","PeriodicalId":75998,"journal":{"name":"Journal of dialysis","volume":"3 2-3","pages":"265-76"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/08860227909063945","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dialysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/08860227909063945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A method has been described and validated for obtaining a sample of blood, without separate venapuncture, which has the same urea and creatinine composition as systemic venous blood during hemodialysis. Using this technique, recirculation in vivo during "Y" type single needle dialysis, measured in 20 bovine fistulas, ranged from 6.9% to 56.5% and averaged 19.4% of blood flow rate as calculated from blood urea nitrogen; and averaged 22.0% with a range of 3.3% to 62.1% of blood flow rate as calculated from serum creatinine concentration. These results suggest that fistula puncture methods and devices that eliminate recirculation in the ex vivo blood circuit should be used to maximize dialysis efficiency.

“Y”型单针透析血液再循环的体内测量。
已经描述并验证了一种方法,用于获得血液样本,而不需要单独的静脉穿刺,其尿素和肌酐组成与血液透析期间的全身静脉血相同。使用该技术,在20个牛瘘管中测量了“Y”型单针透析期间的体内再循环,范围为6.9%至56.5%,平均为19.4%的血流量(由血尿素氮计算);平均为22.0%,根据血清肌酐浓度计算,血流率为3.3% ~ 62.1%。这些结果表明,应该使用消除体外血液循环的瘘管穿刺方法和装置来最大限度地提高透析效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信