Effect of the Coaxial Dielectric Probe Diameter on Its Permittivity Sensing Depth at 2 GHz – Simulation Study

A. Šarolić, Anđela Matković
{"title":"Effect of the Coaxial Dielectric Probe Diameter on Its Permittivity Sensing Depth at 2 GHz – Simulation Study","authors":"A. Šarolić, Anđela Matković","doi":"10.1109/ICECOM48045.2019.9163634","DOIUrl":null,"url":null,"abstract":"We previously reported the simulation results of the RG405-based open-ended coaxial probe model for biological tissue sensing depth analysis. The simulation model with this specific geometry proved valid for calculating the probe perceived permittivity at 2 GHz, triggering a follow-up study on the impact of the probe size on its permittivity sensing depth. In this study, the probe dimensions were upscaled up to five times, while keeping the same relative geometry to maintain the 50 Ω coaxial line impedance. The permittivity sensing depth was again analyzed on both the non-biological water-Teflon model, and biological layered tissue model. The results clearly showed the increased permittivity sensing depth of the larger probes with respect to the smaller ones, at 2 GHz. Nevertheless, the surface layer of the analyzed non-homogeneous samples was the dominant one for all probe sizes.","PeriodicalId":211244,"journal":{"name":"2019 23rd International Conference on Applied Electromagnetics and Communications (ICECOM)","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 23rd International Conference on Applied Electromagnetics and Communications (ICECOM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECOM48045.2019.9163634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We previously reported the simulation results of the RG405-based open-ended coaxial probe model for biological tissue sensing depth analysis. The simulation model with this specific geometry proved valid for calculating the probe perceived permittivity at 2 GHz, triggering a follow-up study on the impact of the probe size on its permittivity sensing depth. In this study, the probe dimensions were upscaled up to five times, while keeping the same relative geometry to maintain the 50 Ω coaxial line impedance. The permittivity sensing depth was again analyzed on both the non-biological water-Teflon model, and biological layered tissue model. The results clearly showed the increased permittivity sensing depth of the larger probes with respect to the smaller ones, at 2 GHz. Nevertheless, the surface layer of the analyzed non-homogeneous samples was the dominant one for all probe sizes.
同轴介质探头直径对2ghz电介电常数探测深度影响的仿真研究
我们之前报道了基于rg405的开放式同轴探针模型用于生物组织传感深度分析的仿真结果。具有这种特定几何形状的仿真模型被证明是有效的,可以计算探针在2 GHz时的感知介电常数,从而引发了对探针尺寸对其介电常数感知深度影响的后续研究。在本研究中,探头尺寸被放大了5倍,同时保持相同的相对几何形状,以保持50 Ω同轴线阻抗。在非生物水-聚四氟乙烯模型和生物层状组织模型上再次分析了介电常数感知深度。结果清楚地表明,在2 GHz时,相对于较小的探针,较大的探针的介电常数传感深度有所增加。然而,所分析的非均匀样品的表层是所有探针尺寸的主导层。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书