{"title":"Studies on A Sample Preparation Method for HR-SEM and Application in Failure Analysis of Trench TEOS Gauging Measurement in Wafer Fabrication","authors":"Z. Siping, H. Younan, Mo Zhi-qiang, Cho Jie Ying","doi":"10.1109/SMELEC.2006.380687","DOIUrl":null,"url":null,"abstract":"To identify nitride from oxide layer on the trench, it is necessary to perform BOE chemical staining. However, chemical staining using BOE will damage the oxide layer, causing inaccurate readings in the oxide gauging measurement in the trench. Moreover, damage on the oxide layer caused heavy charging at the side of the trench and the surface of oxide layer. In this paper, we proposed to coat a Cr layer over the trench before chemical staining. The damage problem was eliminated and the measurement of oxide gauging was more accurate. A application case is discussed for trench TEOS gauging measurement.","PeriodicalId":136703,"journal":{"name":"2006 IEEE International Conference on Semiconductor Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Conference on Semiconductor Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMELEC.2006.380687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

To identify nitride from oxide layer on the trench, it is necessary to perform BOE chemical staining. However, chemical staining using BOE will damage the oxide layer, causing inaccurate readings in the oxide gauging measurement in the trench. Moreover, damage on the oxide layer caused heavy charging at the side of the trench and the surface of oxide layer. In this paper, we proposed to coat a Cr layer over the trench before chemical staining. The damage problem was eliminated and the measurement of oxide gauging was more accurate. A application case is discussed for trench TEOS gauging measurement.
一种HR-SEM样品制备方法及其在晶圆制造中沟槽TEOS测量失效分析中的应用
为了从沟槽上的氧化层中识别氮化物,有必要进行BOE化学染色。但是,使用BOE进行化学染色会损坏氧化层,导致沟槽中氧化测量的读数不准确。此外,氧化层的损伤导致沟槽侧面和氧化层表面大量充注。在本文中,我们建议在化学染色之前在沟槽上涂一层Cr层。消除了损伤问题,使氧化测量更加准确。讨论了战壕TEOS测量的应用实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信