Case Study on Sample Preparation Method to Eliminate the Artifact for Auger Analysis on Bond Pad

Hemalatha Somu
{"title":"Case Study on Sample Preparation Method to Eliminate the Artifact for Auger Analysis on Bond Pad","authors":"Hemalatha Somu","doi":"10.31399/asm.cp.istfa2022p0422","DOIUrl":null,"url":null,"abstract":"\n In today’s advanced technology world, electronic devices are playing a key role in modern semiconductor products to improve the energy proficiency. These devices are required to be contamination free especially on the bond pad with good adhesion before wire bonding process at the back end. Contamination on the bond pad leads to reliability issues such as pad corrosion, delamination and failure leading to leakage and open fails of electronic devices. Therefore, detection accuracy and sensibility of contamination is important. Auger analysis is the most suitable technique to check bond pad contamination. Auger electron spectroscopy has the capability of analyzing compositional information with excellent spatial resolution. However, charging, noise or artifact is known to be a major concern to the characterization of insulating materials. This paper outlines the strategy that has been utilized to minimize the artifact, noise or charging impact for Auger investigation on a smaller bond pad surrounded by imide passivation layers. The imide passivation layer normally causes the charging effect during Auger analysis, which makes the Auger analysis difficult to be proceed. In addition to that, the charging effect leads to inaccurate analysis. In this paper, we demonstrate a sample preparation method to minimize the charging and artifact of Auger analysis especially for small bond pads.","PeriodicalId":417175,"journal":{"name":"International Symposium for Testing and Failure Analysis","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium for Testing and Failure Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.cp.istfa2022p0422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In today’s advanced technology world, electronic devices are playing a key role in modern semiconductor products to improve the energy proficiency. These devices are required to be contamination free especially on the bond pad with good adhesion before wire bonding process at the back end. Contamination on the bond pad leads to reliability issues such as pad corrosion, delamination and failure leading to leakage and open fails of electronic devices. Therefore, detection accuracy and sensibility of contamination is important. Auger analysis is the most suitable technique to check bond pad contamination. Auger electron spectroscopy has the capability of analyzing compositional information with excellent spatial resolution. However, charging, noise or artifact is known to be a major concern to the characterization of insulating materials. This paper outlines the strategy that has been utilized to minimize the artifact, noise or charging impact for Auger investigation on a smaller bond pad surrounded by imide passivation layers. The imide passivation layer normally causes the charging effect during Auger analysis, which makes the Auger analysis difficult to be proceed. In addition to that, the charging effect leads to inaccurate analysis. In this paper, we demonstrate a sample preparation method to minimize the charging and artifact of Auger analysis especially for small bond pads.
结合垫螺旋钻分析中消除伪影的样品制备方法实例研究
在科技发达的今天,电子器件在现代半导体产品中发挥着关键作用,以提高能源利用率。这些设备要求是无污染的,特别是在后端进行金属键合工艺之前,具有良好附着力的键合垫。焊盘上的污染会导致可靠性问题,如焊盘腐蚀、分层和导致电子设备泄漏和打开故障的故障。因此,污染检测的准确性和灵敏度至关重要。螺旋钻分析是检查焊盘污染最合适的技术。俄歇电子能谱具有分析成分信息的能力,具有良好的空间分辨率。然而,充电、噪声或伪影是已知的绝缘材料特性的主要关注点。本文概述了用于在由亚胺钝化层包围的较小键合垫上进行俄歇研究的最小化伪影、噪音或充电影响的策略。在俄歇分析中,亚胺钝化层通常会产生充注效应,使俄歇分析难以进行。除此之外,充电效应导致分析不准确。在本文中,我们演示了一种样品制备方法,以最大限度地减少俄歇分析的电荷和伪影,特别是对小键合垫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信