The capacitor commutated converter (CCC) as an alternative for application in HVDC projects

Â. Rezek, A.A. dos Santos Izidoro, J. Souza de Sa, F.C. da Fonseca
{"title":"The capacitor commutated converter (CCC) as an alternative for application in HVDC projects","authors":"Â. Rezek, A.A. dos Santos Izidoro, J. Souza de Sa, F.C. da Fonseca","doi":"10.1109/ISIE.2003.1267288","DOIUrl":null,"url":null,"abstract":"Series compensated commutation is obtained by inserting a capacitor between the inverter transformer and the six pulse thyristorized Graetz bridge. This arrangement will provide a reduction in the impedance of the commutation circuit. This can permit grater efficiency of commutation, reducing the reactive power consumption of the converter and the consequent necessity of large shunt compensation banks. An improvement in the susceptibility of the converter to commutation failure is achieved, when the converter is operating in the inverter mode. In this paper, the valve commutation process as well as experimental and simulated results of current and voltage waveforms of the CCC, is studied and discussed.","PeriodicalId":166431,"journal":{"name":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2003.1267288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Series compensated commutation is obtained by inserting a capacitor between the inverter transformer and the six pulse thyristorized Graetz bridge. This arrangement will provide a reduction in the impedance of the commutation circuit. This can permit grater efficiency of commutation, reducing the reactive power consumption of the converter and the consequent necessity of large shunt compensation banks. An improvement in the susceptibility of the converter to commutation failure is achieved, when the converter is operating in the inverter mode. In this paper, the valve commutation process as well as experimental and simulated results of current and voltage waveforms of the CCC, is studied and discussed.
电容器整流变流器(CCC)作为高压直流工程的替代方案
通过在逆变变压器和六脉冲晶闸管栅极桥之间插入电容实现串联补偿换相。这种安排将减少整流电路的阻抗。这可以提高换相效率,减少转换器的无功功率消耗,从而减少大型并联补偿组的必要性。当变流器在逆变模式下工作时,变流器对换相故障的敏感性得到了改善。本文对换向过程进行了研究和讨论,并对换向过程的电流和电压波形进行了实验和仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信