{"title":"3D Simulation of Electric Arcing and Pressure increase in an Automotive HVDC Relay During a Short Circuit Situation","authors":"Crispin Masahudu Ewuntomah, J. Oberrath","doi":"10.1109/HLM49214.2020.9307918","DOIUrl":null,"url":null,"abstract":"A short circuit situation in an electric vehicle can lead to several undesirable occurrences. One of such is the formation of high temperature electric arcs between the contacts of the high voltage direct current (HVDC) relays in the circuit. These arcs significantly vaporize the contacts within a few milliseconds. As a result, the pressure of the gas within the relay chamber significantly increases. Depending on the magnitude of the short circuit current, the pressure increase may lead to an explosion of the relay. To understand and quantify the pressure increase, a Panasonic AEV14012 relay is investigated. A short circuit experiment is conducted on the relay. The test results are compared with a numerical model established in COMSOL to simulate the electric arcing process. The temperature of the arcs is used to estimate the resulting vaporization. The simulation results show the arcing process and the resulting pressure increase within the relay chamber.","PeriodicalId":268345,"journal":{"name":"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 66th Holm Conference on Electrical Contacts and Intensive Course (HLM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HLM49214.2020.9307918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A short circuit situation in an electric vehicle can lead to several undesirable occurrences. One of such is the formation of high temperature electric arcs between the contacts of the high voltage direct current (HVDC) relays in the circuit. These arcs significantly vaporize the contacts within a few milliseconds. As a result, the pressure of the gas within the relay chamber significantly increases. Depending on the magnitude of the short circuit current, the pressure increase may lead to an explosion of the relay. To understand and quantify the pressure increase, a Panasonic AEV14012 relay is investigated. A short circuit experiment is conducted on the relay. The test results are compared with a numerical model established in COMSOL to simulate the electric arcing process. The temperature of the arcs is used to estimate the resulting vaporization. The simulation results show the arcing process and the resulting pressure increase within the relay chamber.