CFD Simulation of HVAC System in a Building using ANSYS - Fluent

Imran Ansari, Atul Shankar Sumanb
{"title":"CFD Simulation of HVAC System in a Building using ANSYS - Fluent","authors":"Imran Ansari, Atul Shankar Sumanb","doi":"10.24113/ijoscience.v8i7.488","DOIUrl":null,"url":null,"abstract":"The aim of the study is to simulate the functionality of a HVAC system in different situations, summer and winter time, using specialized software ANSYS-Fluent. A 2D building model was realized and simulating the internal conditions represented the main elements of the study. There are studied the indoor air temperature and air velocity in different conditions. The results are presented as graphs/plots and spectra of interest parameters. HVAC system functionality simulation using ANSYS-Fluent is providing important results for the studied scenario. \nThe study aimed to simulate HVAC system functionality in different situations, summer and winter time, using specialized software ANSYS-Fluent. The realization of 2D building model and simulation of external and internal conditions it represents the main elements of simulation. As general conclusion, it can be stated with certainty that the recently implemented HVAC system reaches its task and provides adequate comfort conditions inside the amphitheater during both seasons. \nThe average velocities, are slightly bigger during summer season, due to higher airflows required. However, this effect doesn’t affect the occupants, because they are lower than the comfort ones. HVAC system functionality simulation using ANSYS-Fluent is providing important results for the studied scenario. This type of analysis can be used for pre-examination of the future projects in order to obtain functional systems and verify the all requirements for the HVAC installation. The results can be used in further analysis for determining the correlations to the main comfort indicators, PMV and PPD.","PeriodicalId":429424,"journal":{"name":"SMART MOVES JOURNAL IJOSCIENCE","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SMART MOVES JOURNAL IJOSCIENCE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24113/ijoscience.v8i7.488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study is to simulate the functionality of a HVAC system in different situations, summer and winter time, using specialized software ANSYS-Fluent. A 2D building model was realized and simulating the internal conditions represented the main elements of the study. There are studied the indoor air temperature and air velocity in different conditions. The results are presented as graphs/plots and spectra of interest parameters. HVAC system functionality simulation using ANSYS-Fluent is providing important results for the studied scenario. The study aimed to simulate HVAC system functionality in different situations, summer and winter time, using specialized software ANSYS-Fluent. The realization of 2D building model and simulation of external and internal conditions it represents the main elements of simulation. As general conclusion, it can be stated with certainty that the recently implemented HVAC system reaches its task and provides adequate comfort conditions inside the amphitheater during both seasons. The average velocities, are slightly bigger during summer season, due to higher airflows required. However, this effect doesn’t affect the occupants, because they are lower than the comfort ones. HVAC system functionality simulation using ANSYS-Fluent is providing important results for the studied scenario. This type of analysis can be used for pre-examination of the future projects in order to obtain functional systems and verify the all requirements for the HVAC installation. The results can be used in further analysis for determining the correlations to the main comfort indicators, PMV and PPD.
基于ANSYS - Fluent的某建筑暖通空调系统CFD仿真
本研究的目的是使用专门的软件ANSYS-Fluent来模拟暖通空调系统在不同情况下(夏季和冬季)的功能。实现了一个二维建筑模型,并模拟了代表研究主要元素的内部条件。研究了不同工况下的室内空气温度和风速。结果以图/图和感兴趣参数谱的形式呈现。利用ANSYS-Fluent进行暖通空调系统功能仿真,为研究场景提供了重要的结果。该研究旨在使用专用软件ANSYS-Fluent模拟暖通空调系统在夏季和冬季不同情况下的功能。实现二维建筑模型和仿真的外部条件和内部条件,它代表了仿真的主要要素。总的来说,可以肯定地说,最近实施的暖通空调系统达到了它的任务,并在两个季节都提供了圆形剧场内部足够的舒适条件。在夏季,由于需要更高的气流,平均速度略大。然而,这种影响不会影响居住者,因为他们比舒适的人低。利用ANSYS-Fluent进行暖通空调系统功能仿真,为研究场景提供了重要的结果。这种类型的分析可用于未来项目的预审,以获得功能系统并验证暖通空调安装的所有要求。结果可用于进一步分析,以确定与主要舒适性指标PMV和PPD的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信