Radiation Effects in Thermal Image Sensors for Earth Observation Missions

L. Gomez Rojas, T. Clatworthy, M. Skipper, Mark Chang, N. Nelms, A. Pérez Albiñana
{"title":"Radiation Effects in Thermal Image Sensors for Earth Observation Missions","authors":"L. Gomez Rojas, T. Clatworthy, M. Skipper, Mark Chang, N. Nelms, A. Pérez Albiñana","doi":"10.1109/REDW.2014.7004582","DOIUrl":null,"url":null,"abstract":"Cobalt60 and heavy ion irradiations of the ULIS UL03041 thermal infrared image sensor were performed to assess its reliability during ESA's EarthCARE mission. Devices were tested up to 10 krad(Si) and 40 MeV/mg/cm2 LET. The sensors have acceptable performance up to at least 10 krad(Si) and are susceptible to SEL down to a LETs of 15.9 MeV/mg/cm2 with an estimated threshold at 12.1 MeV/mg/cm2.","PeriodicalId":223557,"journal":{"name":"2014 IEEE Radiation Effects Data Workshop (REDW)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Radiation Effects Data Workshop (REDW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.2014.7004582","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Cobalt60 and heavy ion irradiations of the ULIS UL03041 thermal infrared image sensor were performed to assess its reliability during ESA's EarthCARE mission. Devices were tested up to 10 krad(Si) and 40 MeV/mg/cm2 LET. The sensors have acceptable performance up to at least 10 krad(Si) and are susceptible to SEL down to a LETs of 15.9 MeV/mg/cm2 with an estimated threshold at 12.1 MeV/mg/cm2.
地球观测任务用热像传感器的辐射效应
在ESA的EarthCARE任务中,ULIS UL03041热红外图像传感器进行了钴60和重离子辐照,以评估其可靠性。器件测试高达10 krad(Si)和40 MeV/mg/cm2 LET。该传感器具有可接受的性能,至少可达10克拉(Si),并且易受SEL影响,低至15.9 MeV/mg/cm2,估计阈值为12.1 MeV/mg/cm2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信