Analysis of Partial Discharge Test of Transformer Caused by Excitation Transformer Fault

Yu Bing, Zhao Lin, Yang Zhi, Yang Yong
{"title":"Analysis of Partial Discharge Test of Transformer Caused by Excitation Transformer Fault","authors":"Yu Bing, Zhao Lin, Yang Zhi, Yang Yong","doi":"10.1109/ICICM48536.2019.8977148","DOIUrl":null,"url":null,"abstract":"Partial discharge refers to a discharge phenomenon in which a portion of a region is discharged due to an electric field and there is no breakdown between the applied voltage conductors in an operating state. For transformers above 110kV, the partial discharge test is an effective means and method for verifying the insulation level of the transformer. Due to the limitations of the field test conditions, the partial discharge test of the transformer generally adopts a low-voltage side compensation press and a method of inducing a test voltage level on the high-voltage side. The state of the test equipment directly determines whether the experimental results meet the standard requirements. In this paper, we analyze the situation that the excitation is self-discharged and then transmitted to the transformer of the test, which results in the test result not meeting the standard requirements. At the same time, the excitation is returned to the factory for disintegration, and the cause of the accident is analyzed to provide experience and support for future field tests. During partial discharge test of transformer, the amount of partial discharge caused by the failure of the test equipment is difficult to distinguish. This type of problem can only be avoided by regular maintenance of the test equipment or by applying a voltage rise to the equipment.","PeriodicalId":257536,"journal":{"name":"2019 IEEE 4th International Conference on Integrated Circuits and Microsystems (ICICM)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Integrated Circuits and Microsystems (ICICM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICM48536.2019.8977148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Partial discharge refers to a discharge phenomenon in which a portion of a region is discharged due to an electric field and there is no breakdown between the applied voltage conductors in an operating state. For transformers above 110kV, the partial discharge test is an effective means and method for verifying the insulation level of the transformer. Due to the limitations of the field test conditions, the partial discharge test of the transformer generally adopts a low-voltage side compensation press and a method of inducing a test voltage level on the high-voltage side. The state of the test equipment directly determines whether the experimental results meet the standard requirements. In this paper, we analyze the situation that the excitation is self-discharged and then transmitted to the transformer of the test, which results in the test result not meeting the standard requirements. At the same time, the excitation is returned to the factory for disintegration, and the cause of the accident is analyzed to provide experience and support for future field tests. During partial discharge test of transformer, the amount of partial discharge caused by the failure of the test equipment is difficult to distinguish. This type of problem can only be avoided by regular maintenance of the test equipment or by applying a voltage rise to the equipment.
励磁变压器故障引起变压器局部放电试验分析
局部放电是指在电场作用下,局部区域被放电,外加电压导体之间在工作状态下没有击穿的放电现象。对于110kV以上的变压器,局部放电试验是验证变压器绝缘水平的有效手段和方法。由于现场试验条件的限制,变压器局部放电试验一般采用低压侧补偿压机和高压侧感应一个试验电压电平的方法。试验设备的状态直接决定了试验结果是否符合标准要求。本文分析了试验中励磁自放电后传输到变压器,导致试验结果不符合标准要求的情况。同时将励磁返厂分解,分析事故原因,为今后的现场试验提供经验和支持。在变压器局部放电试验中,由于试验设备故障引起的局部放电量难以区分。这种类型的问题只能通过定期维护测试设备或通过对设备施加电压上升来避免。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书