Stability limits of a three-phase induction generator supplying single-phase loads

C. Ion, C. Marinescu
{"title":"Stability limits of a three-phase induction generator supplying single-phase loads","authors":"C. Ion, C. Marinescu","doi":"10.1109/ATEE.2013.6563496","DOIUrl":null,"url":null,"abstract":"This paper analyzes the stability limits of an autonomous three-phase induction generator supplying singlephase loads. By using a particular balancing algorithm, varying resistive and resistive-inductive loads are successfully supplied up to a threshold of 85% from the generator power in three-phase mode. As the load active power is increased beyond this limit, the voltage tends to decrease. Experiments are carried out in order to establish the overall system behavior when loaded to full load. They show that it is possible to supply the loads beyond the 85% limit.","PeriodicalId":399638,"journal":{"name":"2013 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE)","volume":"9 15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATEE.2013.6563496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper analyzes the stability limits of an autonomous three-phase induction generator supplying singlephase loads. By using a particular balancing algorithm, varying resistive and resistive-inductive loads are successfully supplied up to a threshold of 85% from the generator power in three-phase mode. As the load active power is increased beyond this limit, the voltage tends to decrease. Experiments are carried out in order to establish the overall system behavior when loaded to full load. They show that it is possible to supply the loads beyond the 85% limit.
提供单相负载的三相感应发电机的稳定性极限
分析了单相负载供电的自主三相感应发电机的稳定性极限。通过使用一种特殊的平衡算法,在三相模式下,变化的电阻性和阻感性负载可以成功地从发电机功率中提供高达85%的阈值。当负载有功功率超过该限值时,电压趋于降低。实验是为了建立加载到满负荷时的整体系统行为。它们表明,有可能提供超过85%限制的负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信