{"title":"Condition Monitoring System of wind generators based on the effect of electrical torque pulsations and generator temperature","authors":"Khaled B. Abdusamad, D. Gao, Linlin Wu, Hui Liu","doi":"10.1109/PEMWA.2014.6912222","DOIUrl":null,"url":null,"abstract":"Due to the increase in the failures of the wind generators, Condition Monitoring System (CMS) plays a significant role in overcoming these failures resulting from the harsh operation conditions. The mechanical, thermal, and electrical analyses can be utilized to detect the faults, which are coming from the wind generators by monitoring the changes in their characteristics under different (normal and abnormal) operation conditions. Observing the trend of the electrical torque pulsations of the wind generators under different conditions is beneficial to perform proper condition monitoring. In this paper, different methodology has been adopted to implement a proper condition monitoring system on the wind generators by evaluating the generator electrical torque based on the mechanical and the acceleration torque. Then, in order to specify the generator faults, the trend of the electrical torque with respect to the rotor angular speed of the wind generator under different operation conditions is analyzed. Further, the rate of change in the generator temperature is considered as well as an indicator to define the health of the wind generators with respect to the induced electrical torque, because of the negative effect of the elevated generator temperature on the induced electrical torque. Case study, which is based upon collected data from actual measurements, is presented in this work in order to demonstrate the adequacy of the proposed model.","PeriodicalId":370712,"journal":{"name":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEMWA.2014.6912222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Due to the increase in the failures of the wind generators, Condition Monitoring System (CMS) plays a significant role in overcoming these failures resulting from the harsh operation conditions. The mechanical, thermal, and electrical analyses can be utilized to detect the faults, which are coming from the wind generators by monitoring the changes in their characteristics under different (normal and abnormal) operation conditions. Observing the trend of the electrical torque pulsations of the wind generators under different conditions is beneficial to perform proper condition monitoring. In this paper, different methodology has been adopted to implement a proper condition monitoring system on the wind generators by evaluating the generator electrical torque based on the mechanical and the acceleration torque. Then, in order to specify the generator faults, the trend of the electrical torque with respect to the rotor angular speed of the wind generator under different operation conditions is analyzed. Further, the rate of change in the generator temperature is considered as well as an indicator to define the health of the wind generators with respect to the induced electrical torque, because of the negative effect of the elevated generator temperature on the induced electrical torque. Case study, which is based upon collected data from actual measurements, is presented in this work in order to demonstrate the adequacy of the proposed model.