The CMS Electromagnetic Calorimeter Data Acquisition System at the 2006 Test Beam.

P. Musella, R. Alemany, N. Almeida, J. Bourotte, F. Beaudette, W. Białas, M. Cerutti, A. David, D. Evans, Y. Geerebaert, P. Gras, M. Husejko, T. Kolberg, A. Paganini, J. C. D. Silva, P. Rumerio, P. Silva, C. Thiebaux, J. Varela, E. Vlassov
{"title":"The CMS Electromagnetic Calorimeter Data Acquisition System at the 2006 Test Beam.","authors":"P. Musella, R. Alemany, N. Almeida, J. Bourotte, F. Beaudette, W. Białas, M. Cerutti, A. David, D. Evans, Y. Geerebaert, P. Gras, M. Husejko, T. Kolberg, A. Paganini, J. C. D. Silva, P. Rumerio, P. Silva, C. Thiebaux, J. Varela, E. Vlassov","doi":"10.1109/RTC.2007.4382836","DOIUrl":null,"url":null,"abstract":"The electromagnetic calorimeter of the CMS experiment at CERN is an homogeneous calorimeter made of about 80000 Lead Tungstate crystals, that will start to operate at the LHC at the end of 2007. From June to November 2006, ten barrel Supermodules (1700 crystals each) were exposed to beam at CERN SPS, both in standalone and in association with portions of the Hadron Calorimeter. We present the description of the system used to configure and readout the calorimeter during the campaign. The full set of final readout electronics boards was employed, together with the pre-series version of the data acquisition software. During the campaign, the hardware and software concepts for the final system were validated. The system allowed the intercalibration of the ten Supermodules and allowed to perform several important studies of the detector performances, such as energy resolution, response linearity and radiation-hardness.","PeriodicalId":217483,"journal":{"name":"2007 15th IEEE-NPSS Real-Time Conference","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 15th IEEE-NPSS Real-Time Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTC.2007.4382836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The electromagnetic calorimeter of the CMS experiment at CERN is an homogeneous calorimeter made of about 80000 Lead Tungstate crystals, that will start to operate at the LHC at the end of 2007. From June to November 2006, ten barrel Supermodules (1700 crystals each) were exposed to beam at CERN SPS, both in standalone and in association with portions of the Hadron Calorimeter. We present the description of the system used to configure and readout the calorimeter during the campaign. The full set of final readout electronics boards was employed, together with the pre-series version of the data acquisition software. During the campaign, the hardware and software concepts for the final system were validated. The system allowed the intercalibration of the ten Supermodules and allowed to perform several important studies of the detector performances, such as energy resolution, response linearity and radiation-hardness.
2006年试验束流上的CMS电磁量热计数据采集系统。
欧洲核子研究中心CMS实验的电磁量热计是一个由大约80000个钨酸铅晶体组成的均匀量热计,将于2007年底在大型强子对撞机上开始运行。从2006年6月到11月,在欧洲核子研究中心SPS上,10个桶状超级模块(每个模块1700个晶体)被暴露在光束中,其中既有独立的,也有与强子量热计的部分相结合的。我们介绍了在活动期间用于配置和读出热量计的系统的描述。采用了全套的最终读出电路板,以及预系列版本的数据采集软件。在活动期间,最终系统的硬件和软件概念得到了验证。该系统允许10个超级模块的相互校准,并允许执行探测器性能的几个重要研究,如能量分辨率,响应线性度和辐射硬度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信