{"title":"Millimeter wave power measurement above 110 GHz","authors":"Y. Lau, T. Denning, C. Oleson","doi":"10.1109/ARFTG.2006.4734350","DOIUrl":null,"url":null,"abstract":"With the power measurement standards above 110 GHz undefined, it is left to individuals to devise the methodology of determining the RF power above 110 GHz. This paper details a simple and repeatable method in measuring RF power up to 1 THz using a calorimeter. Calorimeter power measurement is based on the black body absorption principle - a change in temperature between a known power absorbed to an unknown power absorbed. Performance of various millimeter wave bands RF power data are presented and compared.","PeriodicalId":345451,"journal":{"name":"2006 67th ARFTG Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 67th ARFTG Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2006.4734350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
With the power measurement standards above 110 GHz undefined, it is left to individuals to devise the methodology of determining the RF power above 110 GHz. This paper details a simple and repeatable method in measuring RF power up to 1 THz using a calorimeter. Calorimeter power measurement is based on the black body absorption principle - a change in temperature between a known power absorbed to an unknown power absorbed. Performance of various millimeter wave bands RF power data are presented and compared.