Determination of the noise signatures of various sparkover phenomena on the insulated shield wire of long HVDC lines

G. Sibilant, A. Britten, W. de Villiers
{"title":"Determination of the noise signatures of various sparkover phenomena on the insulated shield wire of long HVDC lines","authors":"G. Sibilant, A. Britten, W. de Villiers","doi":"10.1109/PESAFR.2005.1611858","DOIUrl":null,"url":null,"abstract":"Noise measurements in the power line carrier (PLC) bands of a long HVDC line using an insulated shield wire were taken over a period of 3 to 4 months at a PLC repeater station and the data was analysed. Analysis showed that on some days, very high noise levels were experienced, thereby causing errors in communication between the two converter stations. It was postulated that spark gaps, used together with the shield wire insulators, could be the cause of this extraneous noise. Laboratory work was undertaken in order to determine what the noise signatures from various sparkover events on the shield wire of a long HVDC line would look like in the frequency spectrum. Tests were conducted under AC and DC voltage stresses. The radiated noise levels due to the sparkovers were measured using an inefficient loop antenna and a selective voltmeter. Various noise signatures for the various flashover phenomenon tested, were identified","PeriodicalId":270664,"journal":{"name":"2005 IEEE Power Engineering Society Inaugural Conference and Exposition in Africa","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Power Engineering Society Inaugural Conference and Exposition in Africa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESAFR.2005.1611858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Noise measurements in the power line carrier (PLC) bands of a long HVDC line using an insulated shield wire were taken over a period of 3 to 4 months at a PLC repeater station and the data was analysed. Analysis showed that on some days, very high noise levels were experienced, thereby causing errors in communication between the two converter stations. It was postulated that spark gaps, used together with the shield wire insulators, could be the cause of this extraneous noise. Laboratory work was undertaken in order to determine what the noise signatures from various sparkover events on the shield wire of a long HVDC line would look like in the frequency spectrum. Tests were conducted under AC and DC voltage stresses. The radiated noise levels due to the sparkovers were measured using an inefficient loop antenna and a selective voltmeter. Various noise signatures for the various flashover phenomenon tested, were identified
高压直流长线路绝缘屏蔽线各种火花现象噪声特征的测定
在一个PLC中继站,使用绝缘屏蔽线对一条长高压直流线路的电力线载波(PLC)频段进行了为期3至4个月的噪声测量,并对数据进行了分析。分析表明,在某些日子里,经历了非常高的噪音水平,从而导致两个换流站之间的通信出现错误。据推测,火花间隙与屏蔽线绝缘体一起使用,可能是造成这种外来噪音的原因。为了确定长HVDC线路屏蔽线上各种火花事件的噪声特征在频谱上的样子,进行了实验室工作。试验在交流和直流电压应力下进行。由火花引起的辐射噪声水平使用低效环路天线和选择性电压表进行测量。对所测试的各种闪络现象的各种噪声特征进行了识别
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信