Evolutionary Computation Based Comparative Study of TCPS and CES Control Applied to Automatic Generation Control

S. Ghoshal, R. Roy
{"title":"Evolutionary Computation Based Comparative Study of TCPS and CES Control Applied to Automatic Generation Control","authors":"S. Ghoshal, R. Roy","doi":"10.1109/ICPST.2008.4745331","DOIUrl":null,"url":null,"abstract":"This paper presents the comparative analysis of the optimal transient performance of automatic generation control (AGC) of an interconnected two-area power system, having multiple thermal-hydro-diesel mixed generating units. The significant improvement of optimal transient performance is observed with the addition of a thyristor-controlled phase shifter (TCPS) in the tie-line or small capacitive energy storage (CES) units fitted in both the areas. The optimal values of the gain settings are obtained by three different optimization algorithms. Craziness based particle swarm optimization (CRPSO) proves to be moderately fast algorithm and yields true optimal gains and minimum overshoot, minimum undershoot and minimum settling time of the transient response. Comparative study of TCPS and CES reveals that the CES units fitted in both the areas improve the transient performance to a greater extent following small load disturbance(s) in both the areas.","PeriodicalId":107016,"journal":{"name":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2008.4745331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

This paper presents the comparative analysis of the optimal transient performance of automatic generation control (AGC) of an interconnected two-area power system, having multiple thermal-hydro-diesel mixed generating units. The significant improvement of optimal transient performance is observed with the addition of a thyristor-controlled phase shifter (TCPS) in the tie-line or small capacitive energy storage (CES) units fitted in both the areas. The optimal values of the gain settings are obtained by three different optimization algorithms. Craziness based particle swarm optimization (CRPSO) proves to be moderately fast algorithm and yields true optimal gains and minimum overshoot, minimum undershoot and minimum settling time of the transient response. Comparative study of TCPS and CES reveals that the CES units fitted in both the areas improve the transient performance to a greater extent following small load disturbance(s) in both the areas.
基于进化计算的TCPS与CES控制在自动生成控制中的比较研究
本文对具有多台热水柴油混合发电机组的两区互联电力系统的最优暂态自动发电控制性能进行了对比分析。通过在联络线中添加晶闸管控制移相器(TCPS)或在两个区域安装小型电容储能(CES)单元,可以观察到最佳瞬态性能的显着改善。通过三种不同的优化算法得到增益设置的最优值。基于疯狂度的粒子群优化算法(CRPSO)被证明是一种中等速度的算法,能够获得真正的最优增益,并且能够获得最小的瞬态响应超调量、最小的欠调量和最小的稳定时间。对比研究表明,在负荷扰动较小的情况下,两区均安装了负荷扰动控制单元,在较大程度上改善了两区暂态性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信