{"title":"NOESIS: A nitric oxide exhaled sensor integrated system","authors":"E. Zampetti, A. Bearzotti, A. Macagnano","doi":"10.1109/ATEE.2013.6563530","DOIUrl":null,"url":null,"abstract":"This work describes the results of a handheld sensor system for monitoring exhaled nitric oxide. The device was developed during a framework of 3-year national project “NOESIS” in cooperation with an Italian SME (Medical International Research S.r.l.). In this apparatus a conductive sensor based on titania nanofibers coated with an ultra-thin film of PEDOT:PSS is capable of detecting up to 5 ppb of NO gas. The sensor system implements a smart recirculation measurement methodology to comply recommendations of the American Thoracic Society and European Respiratory Society about the medical instrumentations devoted to monitor and diagnose the respiratory inflammations. Such implemented system executes the measure in 90 seconds, with an exhalation time of about 10 seconds.","PeriodicalId":399638,"journal":{"name":"2013 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATEE.2013.6563530","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work describes the results of a handheld sensor system for monitoring exhaled nitric oxide. The device was developed during a framework of 3-year national project “NOESIS” in cooperation with an Italian SME (Medical International Research S.r.l.). In this apparatus a conductive sensor based on titania nanofibers coated with an ultra-thin film of PEDOT:PSS is capable of detecting up to 5 ppb of NO gas. The sensor system implements a smart recirculation measurement methodology to comply recommendations of the American Thoracic Society and European Respiratory Society about the medical instrumentations devoted to monitor and diagnose the respiratory inflammations. Such implemented system executes the measure in 90 seconds, with an exhalation time of about 10 seconds.
NOESIS:一氧化氮呼出传感器集成系统
这项工作描述了用于监测呼出一氧化氮的手持传感器系统的结果。该装置是在与一家意大利SME(医学国际研究有限公司)合作的为期3年的国家项目“NOESIS”框架内开发的。在该装置中,一种基于二氧化钛纳米纤维的导电传感器,表面涂有PEDOT:PSS超薄薄膜,能够检测到高达5 ppb的NO气体。该传感器系统采用智能循环测量方法,符合美国胸科学会和欧洲呼吸学会关于用于监测和诊断呼吸道炎症的医疗仪器的建议。所实施的系统在90秒内执行测量,呼气时间约为10秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信