{"title":"A commercial multi-line TRL calibration","authors":"L. Hayden","doi":"10.1109/ARFTG.2007.8376226","DOIUrl":null,"url":null,"abstract":"A commercial implementation of the reference multi-line TRL has recently become available [1]. While the algorithm implementation has intentionally been kept as true to the previously published details [2]–[3] as possible, the implementation in a current and supported software application enables new capabilities. In addition to support for reference line Zo and propagation constant determination, Zo renormalization, and error term error bound comparison [4], the new implementation supports a wide-variety of vector network analyzer models. Fully automated MLTRL calibration is enabled by using programmable stage and positioner moves with appropriately equipped semi-automatic probe stations. The automation and improved consistency of probe placement results in dramatically faster and less laborious calibration with better calibration repeatability.","PeriodicalId":199632,"journal":{"name":"2007 70th ARFTG Microwave Measurement Conference (ARFTG)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 70th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2007.8376226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
A commercial implementation of the reference multi-line TRL has recently become available [1]. While the algorithm implementation has intentionally been kept as true to the previously published details [2]–[3] as possible, the implementation in a current and supported software application enables new capabilities. In addition to support for reference line Zo and propagation constant determination, Zo renormalization, and error term error bound comparison [4], the new implementation supports a wide-variety of vector network analyzer models. Fully automated MLTRL calibration is enabled by using programmable stage and positioner moves with appropriately equipped semi-automatic probe stations. The automation and improved consistency of probe placement results in dramatically faster and less laborious calibration with better calibration repeatability.